CoChat

Usefulness of Intracardiac Echocardiography for the Diagnosis of Cardiovascular Implantable Electronic Device–Related Endocarditis

Open access
Narducci, Maria Lucia, Pelargonio, Gemma, Russo, Eleonora, Marinaccio, Leonardo, Di Monaco, Antonio, Perna, Francesco, Bencardino, Gianluigi, Casella, Michela, Di Biase, Luigi, Santangeli, Pasquale, Palmieri, Rosalinda, Lauria, Christian, Al Mohani, Ghaliah, Di Clemente, Francesca, Tondo, Claudio, Pennestri, Faustino, Ierardi, Carolina, Rebuzzi, Antonio G., Crea, Filippo, Bellocci, Fulvio, Natale, Andrea, Russo, Antonio Dello · 2013 · Journal of the American College of Cardiology
Cited by 134

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVES The goal of this study was to compare transesophageal echocardiography (TEE) and intracardiac echocardiography (ICE) for the diagnosis of cardiac device-related endocarditis (CDI). BACKGROUND The diagnosis of infective endocarditis (IE) was established by using the modified Duke criteria based mainly on echocardiography and blood culture results. No previous studies have compared ICE with TEE for the diagnosis of IE. METHODS We prospectively enrolled 162 patients (age 72 ± 11 years; 125 male) who underwent transvenous lead extraction: 152 with CDI and 10 with lead malfunction (control group). Using the modified Duke criteria, we divided the patients with infection into 3 groups: 44 with a "definite" diagnosis of IE (group 1), 52 with a "possible" diagnosis of IE (group 2), and 56 with a "rejected" diagnosis of IE (group 3). TEE and ICE were performed before the procedure. RESULTS In group 1, ICE identified intracardiac masses (ICM) in all 44 patients; TEE identified ICM in 32 patients (73%). In group 2, 6 patients (11%) had ICE and TEE both positive for ICM, 8 patients (15%) had a negative TEE but a positive ICE, and 38 patients (73%) had ICE and TEE both negative. In group 3, 2 patients (3%) had ICM both at ICE and TEE, 1 patient (2%) had an ICM at ICE and a negative TEE, and 53 patients (95%) had no ICM at ICE and TEE. ICE and TEE were both negative in the control group. CONCLUSIONS ICE represents a useful technique for the diagnosis of ICM, thus providing improved imaging of right-sided leads and increasing the diagnostic yield compared with TEE.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2012.12.041

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 134

Metadata

Authors
Narducci, M. L., Pelargonio, G., Russo, E., Marinaccio, L., Di Monaco, A., Perna, F., Bencardino, G., Casella, M., Di Biase, L., Santangeli, P., Palmieri, R., Lauria, C., Al Mohani, G., Di Clemente, F., Tondo, C., Pennestri, F., Ierardi, C., Rebuzzi, A. G., Crea, F., Bellocci, F., Natale, A., & Russo, A. D.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2013-04
Volume
61
Issue
13
Pages
1398-1405
ISSN
0735-1097 (ISSN-L)
OpenAlex
W1987124464
Cited by
134
References
3
FWCI
8.86
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.