The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Ventricular Arrhythmias and Implantable Cardioverter-Defibrillator Therapy in Patients With Continuous-Flow Left Ventricular Assist Devices
Open accessAbstract
OBJECTIVES This study sought to evaluate the prevalence and significance of ventricular arrhythmia (VA) and the role of an implantable cardioverter-defibrillator (ICD) in patients supported by a continuous-flow left ventricular assist device (CF-LVAD). BACKGROUND VAs are common in patients supported by CF-LVADs but prospective data to support the routine use of ICDs in these patients are lacking. METHODS All patients supported by long-term CF-LVAD receiving care at our institution were enrolled. The ICDs were interrogated at baseline and throughout prospective follow-up. The VA was defined as ventricular tachycardia/fibrillation lasting >30 s or effectively terminated by appropriate ICD tachytherapy. The primary outcome was the occurrence of VA >30 days after CF-LVAD implantation. RESULTS Ninety-four patients were enrolled; 77 had an ICD and 17 did not. Five patients with an ICD had it deactivated or a depleted battery not replaced during the study. Twenty-two patients had a VA >30 days after LVAD implantation. Pre-operative VA was the major predictor of post-operative arrhythmia. Absence of pre-operative VA conferred a low risk of post-operative VA (4.0% vs. 45.5%; p < 0.001). No patients discharged from the hospital without an ICD after CF-LVAD implantation died during 276.2 months of follow-up (mean time without ICD, 12.7 ± 12.3 months). CONCLUSIONS Patients with pre-operative VA are at risk of recurrent VA while on CF-LVAD support and should have active ICD therapy to minimize sustained VA. Patients without pre-operative VA are at low risk and may not need active ICD therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Quality of Life with Defibrillator Therapy or Amiodarone in Heart Failure
Mark, D. B., Anstrom, K. J., Sun, J. L., Clapp-Channing, N. E., Tsiatis, A. A., Davidson-Ray, L., Lee, K. L., & Bardy, G. H. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0706719 · Cited by 260
Cited by
Al-Khatib, S. M., Stevenson, W. G., Ackerman, M. J., Bryant, W. J., Callans, D. J., Curtis, A. B., Deal, B. J., Dickfeld, T., Field, M. E., Fonarow, G. C., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.054 · Cited by 1,854
Al-Khatib, S. M., Stevenson, W. G., Ackerman, M. J., Bryant, W. J., Callans, D. J., Curtis, A. B., Deal, B. J., Dickfeld, T., Field, M. E., Fonarow, G. C., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000549 · Cited by 724
Al-Khatib, S. M., Stevenson, W. G., Ackerman, M. J., Bryant, W. J., Callans, D. J., Curtis, A. B., Deal, B. J., Dickfeld, T., Field, M. E., Fonarow, G. C., et al. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2017.10.036 · Cited by 629
2019 EACTS Expert Consensus on long-term mechanical circulatory support
Potapov, E. V., Antonides, C., Crespo-Leiro, M. G., Combes, A., Färber, G., Hannan, M. M., Kukucka, M., de Jonge, N., Loforte, A., Lund, L. H., et al. (2019) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezz098 · Cited by 399
Sandau, K. E., Funk, M., Auerbach, A., Barsness, G. W., Blum, K., Cvach, M., Lampert, R., May, J. L., McDaniel, G. M., Perez, M. V., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000527 · Cited by 342
Metadata
- Authors
- Garan, A. R., Yuzefpolskaya, M., Colombo, P. C., Morrow, J. P., Te-Frey, R., Dano, D., Takayama, H., Naka, Y., Garan, H., Jorde, U. P., & Uriel, N.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2013-06
- Volume
- 61
- Issue
- 25
- Pages
- 2542-2550
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W159146414
- Cited by
- 184
- References
- 2
- FWCI
- 10.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ventricular Arrhythmias and Implantable Cardioverter-Defibrillator Therapy in Patients With Continuous-Flow Left Ventricular Assist Devices. https://app.cochat.ai/papers/10.1016/j.jacc.2013.04.020
- The paper
- Garan, A. R., Yuzefpolskaya, M., Colombo, P. C., Morrow, J. P., Te-Frey, R., Dano, D., Takayama, H., Naka, Y., Garan, H., Jorde, U. P., & Uriel, N. (2013). Ventricular Arrhythmias and Implantable Cardioverter-Defibrillator Therapy in Patients With Continuous-Flow Left Ventricular Assist Devices. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2013.04.020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.