Cited by 1,040Cardiac Valve Diseases and TreatmentsAortic Disease and Treatment ApproachesInfective Endocarditis Diagnosis and Management

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.

Transcatheter Aortic Valve Replacement Using a Self-Expanding Bioprosthesis in Patients With Severe Aortic Stenosis at Extreme Risk for Surgery

Open access

Abstract

Objectives This study sought to evaluate the safety and efficacy of the CoreValve transcatheter heart valve (THV) for the treatment of severe aortic stenosis in patients at extreme risk for surgery.Background Untreated severe aortic stenosis is a progressive disease with a poor prognosis. Transcatheter aortic valve replacement (TAVR) with a self-expanding bioprosthesis is a potentially effective therapy.Methods We performed a prospective, multicenter, nonrandomized investigation evaluating the safety and efficacy of self-expanding TAVR in patients with symptomatic severe aortic stenosis with prohibitive risks for surgery. The primary endpoint was a composite of all-cause mortality or major stroke at 12 months, which was compared with a pre-specified objective performance goal (OPG).Results A total of 41 sites in the United States recruited 506 patients, of whom 489 underwent attempted treatment with the CoreValve THV. The rate of all-cause mortality or major stroke at 12 months was 26.0% (upper 2-sided 95% confidence bound: 29.9%) versus 43.0% with the OPG (p < 0.0001). Individual 30-day and 12-month events included all-cause mortality (8.4% and 24.3%, respectively) and major stroke (2.3% and 4.3%, respectively). Procedural events at 30 days included life-threatening/disabling bleeding (12.7%), major vascular complications (8.2%), and need for permanent pacemaker placement (21.6%). The frequency of moderate or severe paravalvular aortic regurgitation was lower 12 months after self-expanding TAVR (4.2%) than at discharge (10.7%; p = 0.004 for paired analysis).Conclusions TAVR with a self-expanding bioprosthesis was safe and effective in patients with symptomatic severe aortic stenosis at prohibitive risk for surgical valve replacement. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2014.02.556

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Show all 43 references

Cited by

Sorted by citations

Items 801–900 of 1,000

Metadata

Authors
Popma, J. J., Adams, D. H., Reardon, M. J., Yakubov, S. J., Kleiman, N. S., Heimansohn, D., Hermiller, J., Hughes, G. C., Harrison, J. K., Coselli, J., Diez, J., Kafi, A., Schreiber, T., Gleason, T. G., Conte, J., Buchbinder, M., Deeb, G. M., Carabello, B., Serruys, P. W., Chenoweth, S., & Oh, J. K.
Affiliations
  • Beth Israel Deaconess Medical Center (US)
  • Icahn School of Medicine at Mount Sinai (US)
  • Houston Methodist (US)
  • Riverside Methodist Hospital (US)
  • St Vincent Hospital (US)
  • Duke University (US)
  • Baylor St. Luke's Medical Center (US)
  • Detroit Medical Center (US)
  • University of Pittsburgh (US)
  • Johns Hopkins University (US)
  • United States Department of Veterans Affairs (US)
  • University of Michigan (US)
  • Erasmus University Rotterdam (NL)
  • Medtronic (United States) (US)
  • Mayo Clinic (US)
Corresponding author
Popma, Jeffrey J.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2014-05
Volume
63
Issue
19
Pages
1972-1981
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2037507673
Cited by
1,040
References
43
Citations by year
2026: 34 · 2025: 28 · 2024: 57 · 2023: 59 · 2022: 52 · 2021: 76 · 2020: 85 · 2019: 125 · 2018: 108 · 2017: 130 · 2016: 128 · 2015: 113 · 2014: 39
FWCI
94.35
Type
journal article
Language
en
Open access
Locations
  • Journal of the American College of Cardiology (publishedVersion)
  • PubMed (publishedVersion)
  • EUR Research Repository (Erasmus University Rotterdam) (publishedVersion)
  • EUR Research Repository (Erasmus University Rotterdam) (submittedVersion)
Funders
  • Medtronic, Inc
  • Abbott Vascular
  • Abiomed
  • Boston Scientific
  • Cordis
  • Covidien
  • eV3
  • Medtronic
  • CoreValve
  • Edwards Lifesciences
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Aortic Disease and Treatment Approaches
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
Keywords
transcatheter aortic valve implantation, self-expanding bioprosthesis, CoreValve, severe aortic stenosis, high-risk patients, all-cause mortality, major stroke, paravalvular aortic regurgitation, bleeding complications, permanent pacemaker
MeSH terms
Aged, Aged, 80 and over, Aortic Valve Stenosis, Bioprosthesis, Female, Follow-Up Studies, Cardiac Catheterization, Heart Valve Prosthesis, Humans, Male, Prospective Studies, Prosthesis Design, Risk Factors, Severity of Illness Index, Treatment Outcome, Heart Valve Prosthesis Implantation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review