The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
5-Year Outcomes After Left Atrial Appendage Closure
Open accessAbstract
BACKGROUND: The PROTECT AF (WATCHMAN Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) trial demonstrated that left atrial appendage closure (LAAC) with the Watchman device (Boston Scientific, St. Paul, Minnesota) was equivalent to warfarin for preventing stroke in atrial fibrillation, but had a high rate of complications. In a second randomized trial, PREVAIL (Evaluation of the WATCHMAN LAA Closure Device in Patients With Atrial Fibrillation Versus Long Term Warfarin Therapy), the complication rate was low. The warfarin cohort experienced an unexpectedly low ischemic stroke rate, rendering the efficacy endpoints inconclusive. However, these outcomes were based on relatively few patients followed for a relatively short time. OBJECTIVES: The final results of the PREVAIL trial, both alone and as part of a patient-level meta-analysis with the PROTECT AF trial, are reported with patients in both trials followed for 5 years. METHODS: PREVAIL and PROTECT AF are prospective randomized clinical trials with patients randomized 2:1 to LAAC or warfarin; together, they enrolled 1,114 patients for 4,343 patient-years. Analyses are by intention-to-treat, and rates are events per 100 patient-years. RESULTS: For the PREVAIL trial, the first composite coprimary endpoint of stroke, systemic embolism (SE), or cardiovascular/unexplained death did not achieve noninferiority (posterior probability for noninferiority = 88.4%), whereas the second coprimary endpoint of post-procedure ischemic stroke/SE did achieve noninferiority (posterior probability for noninferiority = 97.5%); the warfarin arm maintained an unusually low ischemic stroke rate (0.73%). In the meta-analysis, the composite endpoint was similar between groups (hazard ratio [HR]: 0.820; p = 0.27), as were all-stroke/SE (HR: 0.961; p = 0.87). The ischemic stroke/SE rate was numerically higher with LAAC, but this difference did not reach statistical significance (HR: 1.71; p = 0.080). However, differences in hemorrhagic stroke, disabling/fatal stroke, cardiovascular/unexplained death, all-cause death, and post-procedure bleeding favored LAAC (HR: 0.20; p = 0.0022; HR: 0.45; p = 0.03; HR: 0.59; p = 0.027; HR: 0.73; p = 0.035; HR: 0.48; p = 0.0003, respectively). CONCLUSIONS: These 5-year outcomes of the PREVAIL trial, combined with the 5-year outcomes of the PROTECT AF trial, demonstrate that LAAC with Watchman provides stroke prevention in nonvalvular atrial fibrillation comparable to warfarin, with additional reductions in major bleeding, particularly hemorrhagic stroke, and mortality. (WATCHMAN Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation; NCT00129545; and Evaluation of the WATCHMAN LAA Closure Device in Patients With Atrial Fibrillation Versus Long Term Warfarin Therapy; NCT01182441).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dabigatran versus warfarin in patients with atrial fibrillation
Connolly, S. J., Ezekowitz, M. D., Yusuf, S., Eikelboom, J., Oldgren, J., Parekh, A., Pogue, J., Reilly, P. A., Themeles, E., Varrone, J., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0905561 · Cited by 11,215
Rivaroxaban versus warfarin in nonvalvular atrial fibrillation
Patel, M. R., Mahaffey, K. W., Garg, J., Pan, G., Singer, D. E., Hacke, W., Breithardt, G., Halperin, J. L., Hankey, G. J., Piccini, J. P., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1009638 · Cited by 9,430
Apixaban versus warfarin in patients with atrial fibrillation
Granger, C. B., Alexander, J. H., McMurray, J. J. V., Lopes, R. D., Hylek, E. M., Hanna, M., Al-Khalidi, H. R., Ansell, J., Atar, D., Avezum, A., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1107039 · Cited by 8,943
Edoxaban versus warfarin in patients with atrial fibrillation
Giugliano, R. P., Ruff, C. T., Braunwald, E., Murphy, S. A., Wiviott, S. D., Halperin, J. L., Waldo, A. L., Ezekowitz, M. D., Weitz, J. I., Špinar, J., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1310907 · Cited by 5,164
Ruff, C. T., Giugliano, R. P., Braunwald, E., Hoffman, E. B., Deenadayalu, N., Ezekowitz, M. D., Camm, A. J., Weitz, J. I., Lewis, B. S., Parkhomenko, A., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(13)62343-0 · Cited by 5,051
Hart, R. G., Pearce, L. A., & Aguilar, M. I. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-12-200706190-00007 · Cited by 4,793 · cited 1×
“NOAC = nonwarfarin oral anticoagulation F or decades, oral anticoagulation (OAC) (initially warfarin, and more recently, the nonwarfarin oral anticoagulants [NOACs]) has been the therapeutic mainstay for stroke prophylaxis in atrial fibrillation (AF) (1,2).”
BackgroundHolmes, D. R., Reddy, V. Y., Turi, Z. G., Doshi, S. K., Sievert, H., Buchbinder, M., Mullin, C. M., & Sick, P. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61343-x · Cited by 2,240
Self-citationHolmes, D. R., Kar, S., Price, M. J., Whisenant, B., Sievert, H., Doshi, S. K., Huber, K., & Reddy, V. Y. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.029 · Cited by 1,845
Self-citationFriberg, L., Rosenqvist, M., & Lip, G. Y. H. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr488 · Cited by 1,192
Reddy, V. Y., Sievert, H., Halperin, J., Doshi, S. K., Buchbinder, M., Neuzil, P., Huber, K., Whisenant, B., Kar, S., Swarup, V., et al. (2014) · JAMA · doi:10.1001/jama.2014.15192 · Cited by 1,018
Self-citation
Cited by
Kleindorfer, D. O., Towfighi, A., Chaturvedi, S., Cockroft, K. M., Gutierrez, J., Lombardi-Hill, D., Kamel, H., Kernan, W. N., Kittner, S. J., Leira, E. C., et al. (2021) · Stroke · doi:10.1161/str.0000000000000375 · Cited by 3,237
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
Greenberg, S. M., Ziai, W. C., Cordonnier, C., Dowlatshahi, D., Francis, B., Goldstein, J. N., Hemphill, J. C., Johnson, R., Keigher, K. M., Mack, W. J., et al. (2022) · Stroke · doi:10.1161/str.0000000000000407 · Cited by 1,639
Campbell, B. C. V., & Khatri, P. (2020) · The Lancet · doi:10.1016/s0140-6736(20)31179-x · Cited by 1,116
Metadata
- Authors
- Reddy, V. Y., Doshi, S. K., Kar, S., Gibson, D. N., Price, M. J., Huber, K., Horton, R. P., Buchbinder, M., Neuzil, P., Gordon, N. T., & Holmes, D. R.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2017-12
- Volume
- 70
- Issue
- 24
- Pages
- 2964-2975
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2766540689
- Cited by
- 1,032
- References
- 20
- FWCI
- 52.00
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 5-Year Outcomes After Left Atrial Appendage Closure. https://app.cochat.ai/papers/10.1016/j.jacc.2017.10.021
- The paper
- Reddy, V. Y., Doshi, S. K., Kar, S., Gibson, D. N., Price, M. J., Huber, K., Horton, R. P., Buchbinder, M., Neuzil, P., Gordon, N. T., & Holmes, D. R. (2017). 5-Year Outcomes After Left Atrial Appendage Closure. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2017.10.021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.