Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 176

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Transcatheter Aortic Valve Replacement of Failed Surgically Implanted Bioprostheses

Open access
Tuzcu, E. Murat, Kapadia, Samir R., Vemulapalli, Sreekanth, Carroll, John D., Holmes, David R., Mack, Michael J., Thourani, Vinod H., Grover, Frederick L., Brennan, J. Matthew, Suri, Rakesh M., Dai, David, Svensson, Lars G.·2018·Journal of the American College of Cardiology

Abstract

BACKGROUND Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) has been shown to be feasible, yet the safety and efficacy in relation to native valve (NV) TAVR are not known. OBJECTIVES This study sought to evaluate the safety and effectiveness of ViV TAVR for failed surgical aortic valve replacement (SAVR) by comparing it with the benchmark of NV TAVR. METHODS Patients who underwent ViV-TAVR (n = 1,150) were matched 1:2 (on sex, high or extreme risk, hostile chest or porcelain aorta, 5-m-walk time, and Society of Thoracic Surgeons Predicted Risk of Mortality for reoperation) to patients undergoing NV-TAVR (n = 2,259). Baseline characteristics, procedural data, and in-hospital outcomes were obtained from the Transcatheter Valve Therapy Registry. The 30-day and 1-year outcomes were obtained from linked Medicare administrative claims data. RESULTS Unadjusted analysis revealed lower 30-day mortality (2.9% vs. 4.8%; p < 0.001), stroke (1.7% vs. 3.0%; p = 0.003), and heart failure hospitalizations (2.4% vs. 4.6%; p < 0.001) in the ViV-TAVR compared with NV-TAVR group. Adjusted analysis revealed lower 30-day mortality (hazard ratio: 0.503; 95% confidence interval: 0.302 to 0.839; p = 0.008), lower 1-year mortality (hazard ratio: 0.653; 95% confidence interval: 0.505 to 0.844; p = 0.001), and hospitalization for heart failure (hazard ratio: 0.685; 95% confidence interval: 0.500 to 0.939; p = 0.019) in the ViV-TAVR group. Patients in the ViV-TAVR group had higher post-TAVR mean gradient (16 vs. 9 mm Hg; p < 0.001), but less moderate or severe aortic regurgitation (3.5% vs. 6.6%; p < 0.001). Post-TAVR gradients were highest in small SAVRs and stenotic SAVRs. CONCLUSIONS Comparison with the benchmark NV-TAVR shows ViV-TAVR to be a safe and effective procedure in patients with failed SAVR who are at high risk for repeat surgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2018.04.074

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 176

Metadata

Authors
Tuzcu, E. M., Kapadia, S. R., Vemulapalli, S., Carroll, J. D., Holmes, D. R., Mack, M. J., Thourani, V. H., Grover, F. L., Brennan, J. M., Suri, R. M., Dai, D., & Svensson, L. G.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2018-07
Volume
72
Issue
4
Pages
370-382
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2883554060
Cited by
176
References
4
FWCI
16.69
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transcatheter Aortic Valve Replacement of Failed Surgically Implanted Bioprostheses. https://app.cochat.ai/papers/10.1016/j.jacc.2018.04.074
The paper
Tuzcu, E. M., Kapadia, S. R., Vemulapalli, S., Carroll, J. D., Holmes, D. R., Mack, M. J., Thourani, V. H., Grover, F. L., Brennan, J. M., Suri, R. M., Dai, D., & Svensson, L. G. (2018). Transcatheter Aortic Valve Replacement of Failed Surgically Implanted Bioprostheses. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2018.04.074

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.