The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Prosthesis–Patient Mismatch in Patients Undergoing Transcatheter Aortic Valve Replacement
Open accessAbstract
BACKGROUND Prosthesis-patient mismatch (PPM) after surgical aortic valve replacement (AVR) for aortic stenosis is generally associated with worse outcomes. Transcatheter AVR (TAVR) can achieve a larger valve orifice and the effects of PPM after TAVR are less well studied. OBJECTIVES The authors utilized the Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) registry to examine the frequency, predictors, and association with outcomes of PPM after TAVR in 62,125 patients enrolled between 2014 and 2017. METHODS On the basis of the discharge echocardiographic effective valve area indexed to body surface area, PPM was classified as severe (<0.65 cm2/m2), moderate (0.65 to 0.85 cm2/m2), or none (>0.85 cm2/m2). Multivariable regression models were utilized to examine predictors of severe PPM as well as adjusted outcomes, including mortality, heart failure (HF) rehospitalization, stroke, and quality of life, at 1 year in 37,470 Medicare patients with claims linkage. RESULTS Severe and moderate PPM were present following TAVR in 12% and 25% of patients, respectively. Predictors of severe PPM included small (≤23-mm diameter) valve prosthesis, valve-in-valve procedure, larger body surface area, female sex, younger age, non-white/Hispanic race, lower ejection fraction, atrial fibrillation, and severe mitral or tricuspid regurgitation. At 1 year, mortality was 17.2%, 15.6%, and 15.9% in severe, moderate, and no PPM patients, respectively (p = 0.02). HF rehospitalization had occurred in 14.7%, 12.8%, and 11.9% of patients with severe, moderate, and no PPM, respectively (p < 0.0001). There was no association of severe PPM with stroke or quality-of-life score at 1 year. CONCLUSIONS Severe PPM after TAVR was present in 12% of patients and was associated with higher mortality and HF rehospitalization at 1 year. Further investigation is warranted into the prevention of severe PPM in patients undergoing TAVR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E., Brott, T., Cohen, D., Cutlip, D. E., van Es, G., et al. (2012) · doi:10.48350/15011 · Cited by 3,368
Recommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler Ultrasound
Zoghbi, W. A., Chambers, J. B., Dumesnil, J. G., Foster, E., Gottdiener, J. S., Grayburn, P. A., Khandheria, B. K., Levine, R. A., Marx, G. R., Miller, F. A., et al. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.07.013 · Cited by 1,259
Transcatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical Valves
Dvir, D., Webb, J. G., Bleiziffer, S., Pasic, M., Waksman, R., Kodali, S., Barbanti, M., Latib, A., Schaefer, U., Rodés-Cabau, J., et al. (2014) · JAMA · doi:10.1001/jama.2014.7246 · Cited by 923
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2013) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2012.09.002 · Cited by 918
The problem of valve prosthesis-patient mismatch.
Rahimtoola, S. H. (1978) · Circulation · doi:10.1161/01.cir.58.1.20 · Cited by 853
Head, S. J., Mokhles, M. M., Osnabrugge, R. L. J., Pibarot, P., Mack, M. J., Takkenberg, J. J. M., Bogers, A. J. J. C., & Kappetein, A. P. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs003 · Cited by 522
Outcomes With Transcatheter Mitral Valve Repair in the United States
Sorajja, P., Vemulapalli, S., Feldman, T., Mack, M., Holmes, D. R., Stebbins, A., Kar, S., Thourani, V., & Ailawadi, G. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.09.015 · Cited by 444
Self-citationPibarot, P., Weissman, N. J., Stewart, W. J., Hahn, R. T., Lindman, B. R., McAndrew, T., Kodali, S. K., Mack, M. J., Thourani, V. H., Miller, D. C., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.06.1195 · Cited by 401
Self-citationProsthesis-Patient Mismatch Predicts Structural Valve Degeneration in Bioprosthetic Heart Valves
Flameng, W., Herregods, M.-C., Vercalsteren, M., Herijgers, P., Bogaerts, K., & Meuris, B. (2010) · Circulation · doi:10.1161/circulationaha.109.901272 · Cited by 309
The Incidence and Consequence of Prosthesis-Patient Mismatch After Surgical Aortic Valve Replacement
Fallon, J. M., DeSimone, J. P., Brennan, J. M., O’Brien, S., Thibault, D. P., DiScipio, A. W., Pibarot, P., Jacobs, J. P., & Malenka, D. J. (2018) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2018.01.090 · Cited by 257
Self-citation
Cited by
STS-ACC TVT Registry of Transcatheter Aortic Valve Replacement
Carroll, J. D., Mack, M. J., Vemulapalli, S., Herrmann, H. C., Gleason, T. G., Hanzel, G., Deeb, G. M., Thourani, V. H., Cohen, D. J., Desai, N., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.09.595 · Cited by 1,018
Self-citationSpringhetti, P., Abdoun, K., & Clavel, M.-A. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13144237 · Cited by 24
Metadata
- Authors
- Herrmann, H. C., Daneshvar, S. A., Fonarow, G. C., Stebbins, A., Vemulapalli, S., Desai, N. D., Malenka, D. J., Thourani, V. H., Rymer, J., & Kosinski, A. S.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 72
- Issue
- 22
- Pages
- 2701-2711
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2902226459
- Cited by
- 336
- References
- 28
- FWCI
- 24.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prosthesis–Patient Mismatch in Patients Undergoing Transcatheter Aortic Valve Replacement. https://app.cochat.ai/papers/10.1016/j.jacc.2018.09.001
- The paper
- Herrmann, H. C., Daneshvar, S. A., Fonarow, G. C., Stebbins, A., Vemulapalli, S., Desai, N. D., Malenka, D. J., Thourani, V. H., Rymer, J., & Kosinski, A. S. (2018). Prosthesis–Patient Mismatch in Patients Undergoing Transcatheter Aortic Valve Replacement. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2018.09.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.