Long-Term Durability of Transcatheter Aortic Valve Prostheses

Open access
Blackman, Daniel J., Saraf, Smriti, MacCarthy, Philip A., Myat, Aung, Anderson, Simon G., Malkin, Christopher J., Cunnington, Michael S., Somers, Kathryn, Brennan, Paul, Manoharan, Ganesh, Parker, Jessica, Aldalati, Omar, Brecker, Stephen J., Dowling, Cameron, Hoole, Stephen P., Dorman, Stephen, Mullen, Michael, Kennon, Simon, Jerrum, Melanie, Chandrala, Pavan, Roberts, David H., Tay, Justin, Doshi, Sagar N., Ludman, Peter F., Fairbairn, Timothy A., Crowe, Joanne, Levy, Richard D., Banning, Adrian P., Ruparelia, Neil, Spence, Mark S., Hildick-Smith, David · 2019 · Journal of the American College of Cardiology

Abstract

BACKGROUND Very little is known about long-term valve durability after transcatheter aortic valve replacement (TAVR). OBJECTIVES This study sought to evaluate the incidence of structural valve degeneration (SVD) 5 to 10 years post-procedure. METHODS Demographic, procedural, and in-hospital outcome data on patients who underwent TAVR from 2007 to 2011 were obtained from the U.K. TAVI (United Kingdom Transcatheter Aortic Valve Implantation) registry. Patients in whom echocardiographic data were available both at baseline and ≥5 years post-TAVR were included. Hemodynamic SVD was determined according to European task force committee guidelines. RESULTS A total of 241 patients (79.3 ± 7.5 years of age; 46% female) with paired post-procedure and late echocardiographic follow-up (median 5.8 years, range 5 to 10 years) were included. A total of 149 patients (64%) were treated with a self-expandable valve and 80 (34.7%) with a balloon-expandable valve. Peak aortic valve gradient at follow-up was lower than post-procedure (17.1 vs. 19.1 mm Hg; p = 0.002). More patients had none/trivial aortic regurgitation (AR) (47.5% vs. 33%), and fewer had mild AR (42.5% vs. 57%) at follow-up (p = 0.02). There was 1 case (0.4%) of severe SVD 5.3 years after implantation (new severe AR). There were 21 cases (8.7%) of moderate SVD (mean 6.1 years post-implantation; range 4.9 to 8.6 years). Twelve of these (57%) were due to new AR and 9 (43%) to restenosis. CONCLUSIONS Long-term transcatheter aortic valve function is excellent. In the authors' study, 91% of patients remained free of SVD between 5 and 10 years post-implantation. The incidence of severe SVD was <1%. Moderate SVD occurred in 1 in 12 patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2018.10.078

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 261

Metadata

Authors
Blackman, D. J., Saraf, S., MacCarthy, P. A., Myat, A., Anderson, S. G., Malkin, C. J., Cunnington, M. S., Somers, K., Brennan, P., Manoharan, G., Parker, J., Aldalati, O., Brecker, S. J., Dowling, C., Hoole, S. P., Dorman, S., Mullen, M., Kennon, S., Jerrum, M., Chandrala, P., Roberts, D. H., Tay, J., Doshi, S. N., Ludman, P. F., Fairbairn, T. A., Crowe, J., Levy, R. D., Banning, A. P., Ruparelia, N., Spence, M. S., & Hildick-Smith, D.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2019-02
Volume
73
Issue
5
Pages
537-545
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2914686002
Cited by
261
References
15
FWCI
28.20
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Long-Term Durability of Transcatheter Aortic Valve Prostheses. https://app.cochat.ai/papers/10.1016/j.jacc.2018.10.078
The paper
Blackman, D. J., Saraf, S., MacCarthy, P. A., Myat, A., Anderson, S. G., Malkin, C. J., Cunnington, M. S., Somers, K., Brennan, P., Manoharan, G., Parker, J., Aldalati, O., Brecker, S. J., Dowling, C., Hoole, S. P., Dorman, S., Mullen, M., Kennon, S., Jerrum, M., . . . Hildick-Smith, D. (2019). Long-Term Durability of Transcatheter Aortic Valve Prostheses. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2018.10.078

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.