Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 220

The DOI matches its Crossref record.

Anterior Leaflet Laceration to Prevent Ventricular Outflow Tract Obstruction During Transcatheter Mitral Valve Replacement

Open access
Khan, Jaffar M., Babaliaros, Vasilis C., Greenbaum, Adam B., Foerst, Jason R., Yazdani, Shahram, McCabe, James M., Paone, Gaetano, Eng, Marvin H., Leshnower, Bradley G., Gleason, Patrick T., Chen, Marcus Y., Wang, Dee Dee, Tian, Xin, Stine, Annette M., Rogers, Toby, Lederman, Robert J. · 2019 · Journal of the American College of Cardiology

Abstract

BACKGROUND Left ventricular outflow tract (LVOT) obstruction is a leading cause of mortality and exclusion from transcatheter mitral valve replacement (TMVR). Intentional laceration of the anterior mitral valve leaflet to prevent LVOT obstruction (LAMPOON) is a transcatheter mimic of surgical chord-sparing leaflet resection. OBJECTIVES The purpose of this prospective multicenter trial was to study LAMPOON with transseptal (Edwards Lifesciences, Irvine, California) TMVR in annuloplasty rings or native mitral annular calcification (MAC). METHODS Subjects at high or extreme surgical risk and prohibitive risk of LVOT obstruction from TMVR were included. Eligibility was modified midtrial to exclude subjects with threatened LVOT obstruction from a Sapien 3 valve fabric skirt. The primary endpoint was procedure survival with successful LAMPOON, with successful TMVR, without reintervention, and with LVOT gradient <30 mm Hg (“optimal”) or <50 mm Hg (“acceptable”). Secondary endpoints included 30-day mortality and major adverse cardiovascular events. There was universal source-data verification and independent monitoring. All endpoints were independently adjudicated. Central laboratories analyzed echocardiogram and CT images. RESULTS Between June 2017 and June 2018, 30 subjects were enrolled equally between the MAC and ring arms. LAMPOON traversal and midline laceration was successful in 100%. Procedure survival was 100%, and 30-day survival was 93%. Primary success was achieved in 73%, driven by additional procedures for paravalvular leak (10%) and high-skirt neo-LVOT gradients observed before a protocol amendment. There were no strokes. CONCLUSIONS LAMPOON was feasible in native and annuloplasty ring anatomies in patients who were otherwise ineligible for treatment, with acceptable safety. LAMPOON was effective in preventing LVOT obstruction from TMVR. Despite LAMPOON, TMVR using Sapien 3 in annuloplasty rings and MAC still exhibits important limitations. (NHLBI DIR LAMPOON Study: Intentional Laceration of the Anterior Mitral Leaflet to Prevent Left Ventricular Outflow Tract Obstruction During Transcatheter Mitral Valve Implantation; NCT03015194)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2019.02.076

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 220

Metadata

Authors
Khan, J. M., Babaliaros, V. C., Greenbaum, A. B., Foerst, J. R., Yazdani, S., McCabe, J. M., Paone, G., Eng, M. H., Leshnower, B. G., Gleason, P. T., Chen, M. Y., Wang, D. D., Tian, X., Stine, A. M., Rogers, T., & Lederman, R. J.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2019-05
Volume
73
Issue
20
Pages
2521-2534
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2944944000
Cited by
220
References
0
FWCI
20.70
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Anterior Leaflet Laceration to Prevent Ventricular Outflow Tract Obstruction During Transcatheter Mitral Valve Replacement. https://app.cochat.ai/papers/10.1016/j.jacc.2019.02.076
The paper
Khan, J. M., Babaliaros, V. C., Greenbaum, A. B., Foerst, J. R., Yazdani, S., McCabe, J. M., Paone, G., Eng, M. H., Leshnower, B. G., Gleason, P. T., Chen, M. Y., Wang, D. D., Tian, X., Stine, A. M., Rogers, T., & Lederman, R. J. (2019). Anterior Leaflet Laceration to Prevent Ventricular Outflow Tract Obstruction During Transcatheter Mitral Valve Replacement. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2019.02.076

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.