Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 173

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Long-Term Safety and Efficacy in Continued Access Left Atrial Appendage Closure Registries

Open access
Holmes, David R., Reddy, Vivek Y., Gordon, Nicole T., Delurgio, David, Doshi, Shephal K., Desai, Amish J., Stone, James E., Kar, Saibal · 2019 · Journal of the American College of Cardiology

Abstract

Long-term data on the safety and efficacy of left atrial appendage closure (LAAC) for stroke prevention in patients with nonvalvular atrial fibrillation remain limited. The purpose of this study was to evaluate 4.5- to 5-year data in 2 U.S. Food and Drug Association LAAC mandated registries (CAP [Continued Access to PROTECT-AF] and CAP2 [Continued Access to PREVAIL]) for safety and efficacy. Two registries of patients implanted with LAAC devices provide the largest source of follow-up data. Both accompanied their respective randomized clinical trials, PROTECT-AF (Watchman Left Atrial Appendage System for Embolic PROTECTion in Patients With Atrial Fibrillation) and PREVAIL (Prospective Randomized Evaluation of the WATCHMAN LAA Closure Device In Patients with Atrial Fibrillation versus Long Term Warfarin Therapy), which used the same endpoints (primary efficacy of composite of stroke, systemic embolism, cardiovascular/unexplained death, and safety). CAP included 566 patients with an average follow-up of 50.1 months (2,293 patient-years), and CAP2 included 578 patients with an average follow-up of 50.3 months (2,227 patient-years). CAP2 patients were significantly older and had higher CHA2DS2-VASc (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, stroke/transient ischemic attack, vascular disease, age 65 to 74 years, sex category) scores (4.51 vs. 3.88; p < 0.001). Procedural success was similar in both (94%). The primary composite endpoint occurred at a rate of 3.05 per 100 patient-years in CAP and 4.80 per 100 patient-years in CAP2; events contributing to this endpoint were most commonly cardiovascular/unexplained death (1.69 per 100 patient-years for CAP and 2.92 per 100 patient-years for CAP2). Hemorrhagic stroke was significantly less than ischemic stroke (0.17 per 100 patient-years in CAP and 0.09 per 100 patient-years in CAP2), and total stroke rates were significantly less than predicted by CHA2DS2-VASc score (78% reduction with CAP, 69% reduction with CAP2). These registries, which contain the longest and largest follow-up data of patients with the Watchman device, support LAAC as a safe and effective therapy for long-term anticoagulation in patients with nonvalvular atrial fibrillation, and document the lowest rate of hemorrhagic stroke identified in this population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2019.09.064

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 173

Metadata

Authors
Holmes, D. R., Reddy, V. Y., Gordon, N. T., Delurgio, D., Doshi, S. K., Desai, A. J., Stone, J. E., & Kar, S.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2019-12
Volume
74
Issue
23
Pages
2878-2889
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2990648202
Cited by
173
References
2
FWCI
13.53
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.