CoChat

Transvalvular Flow, Sex, and Survival After Valve Replacement Surgery in Patients With Severe Aortic Stenosis

Open access
Guzzetti, Ezequiel, Poulin, Anthony, Annabi, Mohamed-Salah, Zhang, Bin, Kalavrouziotis, Dimitri, Couture, Christian, Dagenais, François, Pibarot, Philippe, Clavel, Marie-Annick · 2020 · Journal of the American College of Cardiology
Cited by 67

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

BACKGROUND The respective impacts of transvalvular flow, gradient, sex, and their interactions on mortality in patients with severe aortic stenosis undergoing surgical aortic valve replacement (AVR) are unknown. OBJECTIVES This study sought to compare the impact of pre-operative flow-gradient patterns on mortality after AVR and to examine whether there are sex differences. METHODS This study analyzed clinical, echocardiographic, and outcome data prospectively collected in 1,490 patients (544 women [37%]), with severe aortic stenosis and preserved left ventricular ejection fraction who underwent AVR. RESULTS In this cohort, 601 patients (40%) had normal flow (NF) with high gradient (HG), 405 (27%) NF with low gradient (LG), 246 (17%) paradoxical low flow (LF)/HG, and 238 (16%) LF/LG. During a median follow-up of 2.42 years (interquartile range: 1.04 to 4.29 years), 167 patients died. Patients with LF/HG exhibited the highest mortality after AVR (hazard ratio [HR]: 2.01; 95% confidence interval [CI]: 1.33 to 3.03; p < 0.01), which remained significant after multivariate adjustment (HR: 1.96; 95% CI: 1.29 to 2.98; p < 0.01). Both LF/LG and NF/LG patients had comparable outcome to NF/HG (p ≥ 0.47). Optimal thresholds of stroke volume index were obtained for men (40 ml/m2) and women (32 ml/m2). Using these sex-specific cutpoints, paradoxical LF was independently associated with increased mortality in both women (adjusted HR: 2.05; 95% CI: 1.21 to 3.47; p < 0.01) and men (adjusted HR: 1.54; 95% CI: 1.02 to 2.32; p = 0.042), whereas guidelines' threshold (35 ml/m2) does not. CONCLUSIONS Paradoxical LF/HG was associated with higher mortality following AVR, suggesting that a reduced flow is a marker of disease severity even in patients with HG aortic stenosis. Early surgical AVR (i.e., before gradient attains 40 mm Hg) might be preferable in these patients. Furthermore, the use of sex-specific thresholds (<40 ml/m2 for men and <32 ml/m2 for women) to define low-flow outperforms the guidelines' threshold of 35 ml/m2 in risk stratification after AVR.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2020.02.065

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Guzzetti, E., Poulin, A., Annabi, M.-S., Zhang, B., Kalavrouziotis, D., Couture, C., Dagenais, F., Pibarot, P., & Clavel, M.-A.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2020-04
Volume
75
Issue
16
Pages
1897-1909
ISSN
0735-1097 (ISSN-L)
OpenAlex
W3016944184
Cited by
67
References
7
FWCI
4.89
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.