The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Catheter Ablation for Atrial Fibrillation in Heart Failure Patients
Open accessAbstract
Background Rhythm control with antiarrhythmic drugs (AADs) is not superior to rate control in patients with heart failure (HF) and atrial fibrillation (AF), but AF ablation may be more successful at achieving rhythm control than AADs. However, risks for both ablation and AADs are likely higher and success rates lower in patients with HF.Objective To compare rate control versus AF catheter ablation strategies in patients with AF and HF.Methods We conducted a meta-analysis of trials which randomized HF patients (LVEF<50%) with AF to a rate control or AF catheter ablation strategy and reported change in LVEF, quality of life, 6-minute walk test, or peak oxygen consumption. Study quality and heterogenity were assessed using Jadad scores and Cochran's Q statistics, respectively. Mantel Haenszel relative risks and mean differences were calculated using random effect models.Results Four trials (N=224) met inclusion criteria; 82.5% (n=185) had persistent AF. AF ablation was associated with an increase in LVEF (mean difference 8.5%; 95%CI 6.4,10.7%; P<0.001) compared to rate control. AF ablation was superior in improving quality of life by Minnesota Living with Heart Failure (MLWHF) questionnaire scores (mean difference -11.9; 95%CI -17.1, -6.6; P<0.001). Peak oxygen consumption and 6-minute walk distance increased in AF ablation compared to rate control patients (mean difference 3.2; 95%CI 1.1,5.2; P=0.003; mean difference 34.8; 95%CI 2.9, 66.7; P = 0.03, respectively). In the persistent AF subgroup LVEF and MLWHF were significantly improved with AF ablation. Major adverse event rates (RR 1.3; 95% CI, 0.4, 3.9; p=0.64) were not significantly different. No significant heterogeneity was evident.Conclusions In patients with HF and AF, AF catheter ablation is superior to rate control in improving LVEF, quality of life and functional capacity. Prior to accepting a rate control strategy in HF patients with persistent or drug refractory AF, consideration should be given to AF ablation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and reduced hospitalizations, 720, 777 especially in patients without a previous myocardial infarction.780”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [720]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000100 · Cited by 28,164
Dermyshi, E., Wang, Y., Yan, C., Hong, W., Qiu, G., Gong, X., & Zhang, T. (2017) · Neonatology · doi:10.1159/000454668 · Cited by 24,586
Assessing the quality of reports of randomized clinical trials: Is blinding necessary?
Jadad, A. R., Moore, R. A., Carroll, D., Jenkinson, C., Reynolds, D. J. M., Gavaghan, D. J., & McQuay, H. J. (1996) · Controlled Clinical Trials · doi:10.1016/0197-2456(95)00134-4 · Cited by 17,582
Operating characteristics of a rank correlation test for publication bias
Begg, C. B., & Mazumdar, M. (1994) · Biometrics · doi:10.2307/2533446 · Cited by 16,955
Zhang, Q., Wang, C., Zheng, M., Li, Y., Li, J., Zhang, L., Shang, X., & Yan, C. (2014) · Cerebrovascular Diseases · doi:10.1159/000369778 · Cited by 11,609
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.06.006 · Cited by 10,578
Dong, Y., Hao, L., Shi, Z., Wang, G., Zhang, Z., & Han, C. (2013) · Urologia Internationalis · doi:10.1159/000351405 · Cited by 4,557
Chapter 9: Analysing Data and Undertaking Meta-Analyses
Deeks, J. J., Higgins, J. P. T., & Altman, D. G. (2008) · Cited by 2,782
Gelder, I. C. V., Hagens, V. E., Bosker, H. A., Kingma, J. H., Otto Kamp, B., Kingma, T., Said, S. A., Darmanata, J. I., Timmermans, A. J. M., Tijssen, J. G. P., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa021375 · Cited by 2,355
Flagged first, then by citations
Cited by
Sorted by citations
Items 101–105 of 105
Les techniques ablatives de la fibrillation atriale et leurs résultats
Leclercq, C. (2024) · Bulletin de l Académie Nationale de Médecine · doi:10.1016/j.banm.2024.04.004
Ablation of Persistent and Long-Standing Persistent Atrial Fibrillation
Montgomery, J. A., Kowal, J. L., & Michaud, G. F. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-93110-6.00020-7
Gender and Socioeconomic Bias in the Management and Mortality of Patients with Atrial Fibrillation
Alodetalah, Z., MAHDAWI, T. E., Haddadin, F., Elmouhayyar, C., Fram, M., Hammad, N., Jabri, A., Alodetalah, F., & Haddadin, F. (2026) · Women s Health Reports · doi:10.1177/26884844261430617
Almani, M. U., Yousuf, M., Fatima, N., Ullah, M. Q., & Arshad, M. H. (2026) · Advances in Public Health · doi:10.1155/adph/4771111
Post-AF ablation anticoagulation: Real-world practice and predictors of therapy
Zeitler, E. P., Louder, A. M., Yuan, Z., Khanna, R., Rivera, M., Zhang, S., Lopez, J., Oztop, I., Lu, W., Coplan, P., et al. (2026) · Heart Rhythm · doi:10.1016/j.hrthm.2026.09.002
Metadata
- Authors
- Al Halabi, S., Qintar, M., Hussein, A., Alraies, M. C., Jones, D. G., Wong, T., MacDonald, M. R., Petrie, M. C., Cantillon, D., Tarakji, K. G., Kanj, M., Bhargava, M., Varma, N., Baranowski, B., Wilkoff, B. L., Wazni, O., Callahan, T., Saliba, W., & Chung, M. K.
- Affiliations
- Cleveland Clinic (US)
- University of Minnesota (US)
- National Health Service (GB)
- Golden Jubilee National Hospital (GB)
- Corresponding author
- Chung, Mina K.
- ORCID
- Venue
- JACC. Clinical electrophysiology
- Publisher
- Elsevier BV
- Published
- 2015-06
- Volume
- 1
- Issue
- 3
- Pages
- 200-209
- ISSN
- 2405-500X (ISSN-L)
- PMC
- PMC4525704
- OpenAlex
- W952936096
- Cited by
- 105
- References
- 42
- Citations by year
- 2026: 4 · 2025: 2 · 2024: 9 · 2023: 4 · 2022: 6 · 2021: 12 · 2020: 11 · 2019: 19 · 2018: 17 · 2017: 14 · 2016: 6 · 2015: 1
- FWCI
- 9.21
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- JACC. Clinical electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- ENLIGHTEN (Jurnal Bimbingan dan Konseling Islam) (submittedVersion)
- Funders
- National Institutes of Health (R01HL111314)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- atrial fibrillation, heart failure, catheter ablation, rate control, antiarrhythmic drugs, left ventricular ejection fraction, quality of life, functional capacity, persistent atrial fibrillation, major adverse events, Minnesota Living with Heart Failure Questionnaire, 6-minute walk test, peak oxygen uptake, drug-refractory atrial fibrillation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review