Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 236

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Evaluation of the Criteria to Distinguish Left Bundle Branch Pacing From Left Ventricular Septal Pacing

Open access
Wu, Shengjie, Chen, Xueying, Wang, Songjie, Xu, Lei, Xiao, Fangyi, Huang, Zhouqing, Zheng, Rujie, Jiang, Limeng, Vijayaraman, Pugazhendhi, Sharma, Parikshit S., Su, Lan, Huang, Weijian·2021·JACC: Clinical Electrophysiology

Abstract

OBJECTIVES This study sought to assess the predictive value of the proposed electrocardiogram and intracardiac electrogram characteristics for confirmation of left bundle branch (LBB) capture. BACKGROUND Previously proposed criteria to distinguish left bundle branch pacing (LBBP) and left ventricular septum (LVS) pacing (LVSP) have not been fully validated. METHODS A His bundle pacing lead, an LBBP lead, and a multielectrode catheter at the LVS were placed. Direct LBB capture was defined as demonstration of retrograde His potential on the His bundle pacing lead and/or anterograde left conduction system potentials on the multielectrode catheter during LBBP. The routinely used parameters-His, LBB potential, time from stimulus to left ventricular activation (Stim-LVAT), and paced QRS morphology during LVSP and LBBP at various depths and outputs were analyzed. RESULTS Thirty patients (21 non-left bundle branch block [LBBB], 9 LBBB) who demonstrated direct LBB capture using the defined criteria were included. The proportion of paced right bundle branch block was 100% during LBB capture in all patients compared to 23.4% in non-LBBB and 44.4% in LBBB during LVSP. LBB potential was recorded in all patients during intrinsic rhythm (non-LBBB group) or His corrective pacing in LBBB. Paced QRS duration was longer during selective LBBP compared to nonselective LBBP or LVSP only. All patients with characteristics of selective LBBP or abrupt decrease in Stim-LVAT of ≥10 ms demonstrated LBB capture. CONCLUSIONS Direct LBB capture can be confirmed by recording retrograde His potential and anterograde left conduction system potentials. Abrupt decrease in Stim-LVAT of ≥10 ms and demonstration of selective LBBP could be used as simple criteria to confirm LBB capture.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacep.2021.02.018

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 236

Metadata

Authors
Wu, S., Chen, X., Wang, S., Xu, L., Xiao, F., Huang, Z., Zheng, R., Jiang, L., Vijayaraman, P., Sharma, P. S., Su, L., & Huang, W.
Venue
JACC: Clinical Electrophysiology
Publisher
Elsevier BV
Published
2021-09
Volume
7
Issue
9
Pages
1166-1177
ISSN
2405-500X (ISSN-L)
OpenAlex
W3158308283
Cited by
236
References
2
FWCI
26.88
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of the Criteria to Distinguish Left Bundle Branch Pacing From Left Ventricular Septal Pacing. https://app.cochat.ai/papers/10.1016/j.jacep.2021.02.018
The paper
Wu, S., Chen, X., Wang, S., Xu, L., Xiao, F., Huang, Z., Zheng, R., Jiang, L., Vijayaraman, P., Sharma, P. S., Su, L., & Huang, W. (2021). Evaluation of the Criteria to Distinguish Left Bundle Branch Pacing From Left Ventricular Septal Pacing. JACC: Clinical Electrophysiology. https://doi.org/10.1016/j.jacep.2021.02.018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.