The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Evaluation of the Criteria to Distinguish Left Bundle Branch Pacing From Left Ventricular Septal Pacing
Open accessAbstract
OBJECTIVES This study sought to assess the predictive value of the proposed electrocardiogram and intracardiac electrogram characteristics for confirmation of left bundle branch (LBB) capture. BACKGROUND Previously proposed criteria to distinguish left bundle branch pacing (LBBP) and left ventricular septum (LVS) pacing (LVSP) have not been fully validated. METHODS A His bundle pacing lead, an LBBP lead, and a multielectrode catheter at the LVS were placed. Direct LBB capture was defined as demonstration of retrograde His potential on the His bundle pacing lead and/or anterograde left conduction system potentials on the multielectrode catheter during LBBP. The routinely used parameters-His, LBB potential, time from stimulus to left ventricular activation (Stim-LVAT), and paced QRS morphology during LVSP and LBBP at various depths and outputs were analyzed. RESULTS Thirty patients (21 non-left bundle branch block [LBBB], 9 LBBB) who demonstrated direct LBB capture using the defined criteria were included. The proportion of paced right bundle branch block was 100% during LBB capture in all patients compared to 23.4% in non-LBBB and 44.4% in LBBB during LVSP. LBB potential was recorded in all patients during intrinsic rhythm (non-LBBB group) or His corrective pacing in LBBB. Paced QRS duration was longer during selective LBBP compared to nonselective LBBP or LVSP only. All patients with characteristics of selective LBBP or abrupt decrease in Stim-LVAT of ≥10 ms demonstrated LBB capture. CONCLUSIONS Direct LBB capture can be confirmed by recording retrograde His potential and anterograde left conduction system potentials. Abrupt decrease in Stim-LVAT of ≥10 ms and demonstration of selective LBBP could be used as simple criteria to confirm LBB capture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, W., Su, L., Wu, S., Xu, L., Xiao, F., Zhou, X., & Ellenbogen, K. A. (2017) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2017.09.013 · Cited by 736
Self-citationVijayaraman, P., Subzposh, F. A., Naperkowski, A., Panikkath, R., John, K., Mascarenhas, V., Bauch, T. D., & Huang, W. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.05.011 · Cited by 396
Self-citation
Cited by
Burri, H., Jastrzebski, M., Cano, Ó., Čurila, K., de Pooter, J., Huang, W., Israel, C., Joza, J., Romero, J., Vernooy, K., et al. (2023) · Europace · doi:10.1093/europace/euad043 · Cited by 432
Self-citation
Metadata
- Authors
- Wu, S., Chen, X., Wang, S., Xu, L., Xiao, F., Huang, Z., Zheng, R., Jiang, L., Vijayaraman, P., Sharma, P. S., Su, L., & Huang, W.
- Venue
- JACC: Clinical Electrophysiology
- Publisher
- Elsevier BV
- Published
- 2021-09
- Volume
- 7
- Issue
- 9
- Pages
- 1166-1177
- ISSN
- 2405-500X (ISSN-L)
- OpenAlex
- W3158308283
- Cited by
- 236
- References
- 2
- FWCI
- 26.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of the Criteria to Distinguish Left Bundle Branch Pacing From Left Ventricular Septal Pacing. https://app.cochat.ai/papers/10.1016/j.jacep.2021.02.018
- The paper
- Wu, S., Chen, X., Wang, S., Xu, L., Xiao, F., Huang, Z., Zheng, R., Jiang, L., Vijayaraman, P., Sharma, P. S., Su, L., & Huang, W. (2021). Evaluation of the Criteria to Distinguish Left Bundle Branch Pacing From Left Ventricular Septal Pacing. JACC: Clinical Electrophysiology. https://doi.org/10.1016/j.jacep.2021.02.018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.