Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 211

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

A Randomized Trial of His Pacing Versus Biventricular Pacing in Symptomatic HF Patients With Left Bundle Branch Block (His-Alternative)

Open access
Vinther, Michael, Risum, Niels, Svendsen, Jesper Hastrup, Møgelvang, Rasmus, Philbert, Berit Thornvig · 2021 · JACC: Clinical Electrophysiology

Abstract

OBJECTIVES This study sought to compare 2 ways of achieving cardiac resynchronization. BACKGROUND Cardiac resynchronization therapy (CRT) in patients with symptomatic heart failure and left bundle branch block (LBBB) can be achieved with His-bundle pacing correcting the bundle branch block (His-CRT). The present study is the largest randomized study comparing His-CRT and biventricular pacing (BiV-CRT) to date. METHODS Fifty patients with symptomatic heart failure, left ventricular ejection fraction (LVEF) ≤35% and LBBB according to electrocardiography were randomized 1:1 to His-CRT or BiV-CRT and followed for 6 months. At implantation, 7 patients crossed over from His-pacing to LV-pacing in the His-CRT group and 1 patient crossed over from LV-pacing to His-pacing in the BiV-CRT group. RESULTS His-corrective pacing was achieved in 72% of the patients in the His-CRT group. Intention-to-treat 6-month follow-up LVEF increased by 16 ± 7% in the His-CRT group compared with 13 ± 6% in the BiV-CRT group (nonsignificant) and improvements were seen in clinical and physical parameters in both treatment arms with no significant differences between the groups. Pacing thresholds were higher for His-CRT compared with BiV-CRT both at implantation (1.8 ± 1.2 V vs. 1.2 ± 0.8 V; p < 0.01) and at 6-month follow-up (2.3 ± 1.4 V vs. 1.4 ± 0.5 V; p < 0.01). The per-protocol LVEF was significantly higher at 6 months (48 ± 8% vs. 42 ± 8%; p < 0.05) and the end-systolic volume was lower (65 ± 22 ml vs. 83 ± 27 ml; p < 0.05) in His-CRT patients compared with BiV-CRT. CONCLUSIONS In heart failure patients with LBBB, His-CRT provided similar clinical and physical improvement compared with BiV-CRT at the expense of higher pacing thresholds.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacep.2021.04.003

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 211

Metadata

Authors
Vinther, M., Risum, N., Svendsen, J. H., Møgelvang, R., & Philbert, B. T.
Venue
JACC: Clinical Electrophysiology
Publisher
Elsevier BV
Published
2021-11
Volume
7
Issue
11
Pages
1422-1432
ISSN
2405-500X (ISSN-L)
OpenAlex
W3158394354
Cited by
211
References
3
FWCI
23.52
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.