Clinical Impact of Residual Leaks Following Left Atrial Appendage Occlusion
Open accessThe DOI matches its Crossref record.
Abstract
Background: Data on the impact of residual peri-device leak following left atrial appendage occlusion [LAAO] are limited. Objective: to explore the association of peri-device leak with adverse clinical events. Methods: We queried the NCDR-LAAO Registry to identify patients undergoing LAAO between January-1st, 2016, and December-31st, 2019. Patients were classified according to leak size on 45+/−14 days echocardiography: (0mm, no leak; >0–5mm, small leak; >5mm, large leak). Results: A total of 51,333 patients were included, of whom 37,696 (73.4%) had no leak, 13,258 (25.8%) had small leaks, and 379 (0.7%) had large leaks. The proportion of patients on warfarin at 45-day was higher in the large vs. small or no leak cohort (44.9% vs. 34.4% and 32.4%, respectively, p<0.001). At 6- and 12-month, anticoagulant utilization decreased but remained more frequent in patients with large leaks. Thromboembolic events were uncommon in all groups. However, compared with patients with no leak, those with small leaks had slightly higher odds of stroke/TIA/systemic embolization (adjusted hazard ratio [aHR] 1.152, 95%CI 1.025–1.294), major bleeding (HR 1.11, 95%CI 1.029–1.120), and any major adverse events (HR 1.102, 95%CI 1.048–1.160). There were no significant differences in adverse events between patients with large leaks and patients with small or no leaks. Conclusion: Small (0–5mm) leaks after LAAO were associated with modestly higher incidences of thromboembolic and bleeding events; large leaks (>5mm) were not associated with adverse events although higher proportions of these patients were maintained on anticoagulation. Newer devices with improved seal might mitigate the events associated with residual leaks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
Self-citation
Metadata
- Authors
- Alkhouli, M., Du, C., Killu, A., Simard, T., Noseworthy, P. A., Friedman, P. A., Curtis, J. P., Freeman, J. V., & Holmes, D. R.
- Venue
- JACC: Clinical Electrophysiology
- Publisher
- Elsevier BV
- Published
- 2022-06
- Volume
- 8
- Issue
- 6
- Pages
- 766-778
- ISSN
- 2405-500X (ISSN-L)
- OpenAlex
- W4226021146
- Cited by
- 182
- References
- 0
- FWCI
- 23.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical Impact of Residual Leaks Following Left Atrial Appendage Occlusion. https://app.cochat.ai/papers/10.1016/j.jacep.2022.03.001
- The paper
- Alkhouli, M., Du, C., Killu, A., Simard, T., Noseworthy, P. A., Friedman, P. A., Curtis, J. P., Freeman, J. V., & Holmes, D. R. (2022). Clinical Impact of Residual Leaks Following Left Atrial Appendage Occlusion. JACC: Clinical Electrophysiology. https://doi.org/10.1016/j.jacep.2022.03.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.