The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Long Radiology Workdays Reduce Detection and Accommodation Accuracy
Open accessAbstract
Purpose: To measure diagnostic accuracy of fracture detection, visual accommodation, reading time, and subjective ratings of fatigue and visual strain before and after a day of clinical reading. Methods: Forty attending radiologists and radiology residents viewed 60 de-identified HIPAA compliant bone examinations, half with fractures, once before any clinical reading (Early) and once after a day of clinical reading (Late). Reading time was recorded. Visual accommodation (ability to maintain focus) was measured before and after each reading session. Subjective ratings of symptoms of fatigue and oculomotor strain were collected. The study was approved by local IRBs. Results: Diagnostic accuracy was reduced significantly after a day of clinical reading, with average receiver operating characteristic (ROC) area under the curve (AUC) of 0.885 for Early reading and 0.852 for Late reading (p < 0.05). After a day of image interpretation, visual accommodation was no more variable, though error in visual accommodation was greater (p < 0.01) and subjective ratings of fatigue were higher. Conclusions: After a day of clinical reading, radiologists have reduced ability to focus, increased symptoms of fatigue and oculomotor strain, and reduced ability to detect fractures. Radiologists need to be aware of the effects of fatigue on diagnostic accuracy and take steps to mitigate these effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simulator Sickness Questionnaire: An Enhanced Method for Quantifying Simulator Sickness
Kennedy, R. S., Lane, N. E., Berbaum, K. S., & Lilienthal, M. G. (1993) · The International Journal of Aviation Psychology · doi:10.1207/s15327108ijap0303_3 · Cited by 5,457
Self-citationTheoretical and applied aspects of eye movement research
Stern, J. A. (1985) · Biological Psychology · doi:10.1016/0301-0511(85)90031-6 · Cited by 556
Bhargavan, M., & Sunshine, J. H. (2005) · Radiology · doi:10.1148/radiol.2343031536 · Cited by 280
“Proper” Binormal ROC Curves: Theory and Maximum-Likelihood Estimation
Metz, C. E., & Pan, X. (1999) · Journal of Mathematical Psychology · doi:10.1006/jmps.1998.1218 · Cited by 273
Dimensions of fatigue in different working populations
Åhsberg, E. (2000) · Scandinavian Journal of Psychology · doi:10.1111/1467-9450.00192 · Cited by 239
Profile Analysis of Simulator Sickness Symptoms: Application to Virtual Environment Systems
Kennedy, R. S., Lane, N. E., Lilienthal, M. G., Berbaum, K. S., & Hettinger, L. J. (1992) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1992.1.3.295 · Cited by 169
Self-citationRuchman, R. B., Jaeger, J., Wiggins, E. F., Seinfeld, S. A., Thakral, V., Bolla, S., & Wallach, S. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.07.2307 · Cited by 144
Pan, X., & Metz, C. E. (1997) · Academic Radiology · doi:10.1016/s1076-6332(97)80121-3 · Cited by 112
Perceived fatigue after mental work: an experimental evaluation of a fatigue inventory
Åhsberg, E., Gamberale, F., & Gustafsson, K. (2000) · Ergonomics · doi:10.1080/001401300184594 · Cited by 110
Nakajima, Y., Yamada, K., Imamura, K., & Kobayashi, K. (2008) · Radiation Medicine · doi:10.1007/s11604-008-0259-2 · Cited by 97
Prevalence of Eye Strain Among Radiologists: Influence of Viewing Variables on Symptoms
Vertinsky, T., & Forster, B. B. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.184.2.01840681 · Cited by 84
Measurement of Visual Strain in Radiologists
Krupinski, E. A., & Berbaum, K. S. (2009) · Academic Radiology · doi:10.1016/j.acra.2009.02.008 · Cited by 70
Self-citationAn Update Survey of Academic Radiologists' Clinical Productivity
Lü, Y., Zhao, S., Chu, P., & Arenson, R. L. (2008) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2008.02.018 · Cited by 69
Update on the Diagnostic Radiology Employment Market: Findings Through 2007-2008
Sunshine, J. H., & Maynard, C. D. (2008) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2008.02.007 · Cited by 47
The State of Teleradiology in 2003 and Changes Since 1999
Ebbert, T. L., Meghea, C. I., Iturbe, S., et al. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1310 · Cited by 45
Proposal of an Index to Evaluate Visual Fatigue Induced During Visual Display Terminal Tasks
Murata, A., Uetake, A., Otsuka, M., & Takasawa, Y. (2001) · International Journal of Human-Computer Interaction · doi:10.1207/s15327590ijhc1303_2 · Cited by 41
The Effect of Fatigue on Resident Performance
Christensen, E. E., Dietz, G. W., Murry, R. C., & Moore, J. G. (1977) · Radiology · doi:10.1148/125.1.103 · Cited by 28
On-Call Radiology: Community Standards and Current Trends
Harrigal, C. L., & Erly, W. K. (2007) · Seminars in Ultrasound CT and MRI · doi:10.1053/j.sult.2007.01.007 · Cited by 25
Circadian Variation in Radiology
Gale, A. G., Murray, D., Millar, K., & Worthington, B. S. (1984) · Advances in psychology · doi:10.1016/s0166-4115(08)61848-8 · Cited by 21
Audit of the change in the on-call practices in neuroradiology and factors affecting it
Mukerji, N., Wallace, D., & Mitra, D. (2006) · BMC Medical Imaging · doi:10.1186/1471-2342-6-13 · Cited by 17
On Asthenopia, or Weak-Sightedness.
Mackenzie, W. (1843) · Europe PMC (PubMed Central) · Cited by 10
Cited by
Deep learning for healthcare applications based on physiological signals: A review
Faust, O., Hagiwara, Y., Hong, T. J., Lih, O. S., & Acharya, U. R. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.04.005 · Cited by 1,026
Error and discrepancy in radiology: inevitable or avoidable?
Brady, A. P. (2017) · Insights into Imaging · doi:10.1007/s13244-016-0534-1 · Cited by 570
McDonald, R. J., Schwartz, K. M., Eckel, L. J., Diehn, F. E., Hunt, C. H., Bartholmai, B. J., Erickson, B. J., & Kallmes, D. F. (2015) · Academic Radiology · doi:10.1016/j.acra.2015.05.007 · Cited by 460
Cognitive and System Factors Contributing to Diagnostic Errors in Radiology
Lee, C. S., Nagy, P. G., Weaver, S. J., & Newman-Toker, D. E. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.10375 · Cited by 415
Improving Radiographic Fracture Recognition Performance and Efficiency Using Artificial Intelligence
Guermazi, A., Tannoury, C., Kompel, A. J., Murakami, A. M., Ducarouge, A., Gillibert, A., Li, X., Tournier, A., Lahoud, Y., Jarraya, M., et al. (2022) · Radiology · doi:10.1148/radiol.210937 · Cited by 348
Metadata
- Authors
- Krupinski, E. A., Berbaum, K. S., Caldwell, R. T., Schartz, K. M., & Kim, J.
- Venue
- Journal of the American College of Radiology
- Publisher
- Elsevier BV
- Published
- 2010-09
- Volume
- 7
- Issue
- 9
- Pages
- 698-704
- ISSN
- 1546-1440 (ISSN-L)
- OpenAlex
- W2042716610
- Cited by
- 272
- References
- 21
- FWCI
- 6.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.