CoChat

Improved protocol for measurement of plasma β‐amyloid in longitudinal evaluation of Alzheimer's Disease Neuroimaging Initiative study patients

Open access
Figurski, Michal J., Waligórska, Teresa, Toledo, Jon, Vanderstichele, Hugo, Korecka, Magdalena, Lee, Virginia M.Y., Trojanowski, John Q., Shaw, Leslie M. · 2012 · Alzheimer's & Dementia
Cited by 61

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: The interassay variability and inconsistency of plasma β‐amyloid (Aβ) measurements among centers are major factors precluding the interpretation of results and a substantial obstacle in the meta‐analysis across studies of this biomarker. The goal of this investigation was to address these problems by improving the performance of the bioanalytical method. Methods: We used the Luminex immunoassay platform with a multiplex microsphere‐based reagent kit from Innogenetics. A robotic pipetting system was used to perform crucial steps of the procedure. The performance of this method was evaluated using two kit control samples and two quality control plasma samples from volunteer donors, and by retesting previously assayed patient samples in each run. This setup was applied to process 2454 patient plasma samples from the Alzheimer's Disease Neuroimaging Initiative study biofluid repository. We have additionally evaluated the correlations between our results and cerebrospinal fluid (CSF) biomarker data using mixed‐effects modeling. Results: The average precision values of the kit controls were 8.3% for Aβ 1‐40 and 4.0% for Aβ 1‐42, whereas the values for the plasma quality controls were 6.4% for Aβ 1‐40 and 4.8% for Aβ 1‐42. From the test–retest evaluation, the average precision was 7.2% for Aβ 1‐40 and 4.5% for Aβ 1‐42. The range of final plasma results for Alzheimer's Disease Neuroimaging Initiative patients was 13 to 372 pg/mL (median: 164 pg/mL) for Aβ 1‐40 and 3.5 to 103 pg/mL (median: 39.3 pg/mL) for Aβ 1‐42. We found that sample collection parameters (blood volume and time to freeze) have a small, but significant, influence on the result. No significant difference was found between plasma Aβ levels for patients with Alzheimer's disease and healthy control subjects. We have determined multiple significant correlations of plasma Aβ 1‐42 levels with CSF biomarkers. The relatively strongest, although modest, correlation was found between plasma Aβ 1‐42 levels and CSF p‐tau 181/Aβ 1‐42 ratio in patients with mild cognitive impairment. Plasma Aβ 1‐40 correlations with CSF biomarkers were weaker and diminished completely when we used longitudinal data. No significant correlations were found for the plasma Aβ 1‐42/Aβ 1‐40 ratio. Conclusions: The precision of our robotized method represents a substantial improvement over results reported in the literature. Multiple significant correlations between plasma and CSF biomarkers were found. Although these correlations are not strong enough to support the use of plasma Aβ measurement as a diagnostic screening test, plasma Aβ 1‐42 levels are well suited for use as a pharmacodynamic marker.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jalz.2012.01.001

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Figurski, M. J., Waligórska, T., Toledo, J., Vanderstichele, H., Korecka, M., Lee, V. M. Y., Trojanowski, J. Q., & Shaw, L. M.
Venue
Alzheimer's & Dementia
Publisher
Wiley
Published
2012-07
Volume
8
Issue
4
Pages
250-260
ISSN
  • 1552-5260 (ISSN-L)
  • 1552-5279
OpenAlex
W2041004450
Cited by
61
References
3
FWCI
4.53
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.