CoChat
Cited by 229

The DOI matches its Crossref record.

Bacterial Adherence to Surgical Sutures: Can Antibacterial-Coated Sutures Reduce the Risk of Microbial Contamination?

Edmiston, Charles E., Seabrook, Gary R., Goheen, Michael P., Krepel, Candace J., Johnson, Christopher P., Lewis, Brian D., Brown, Kellie R., Towne, Jonathan B. · 2006 · Journal of the American College of Surgeons

Abstract

BACKGROUND: Surgical site infections are associated with severe morbidity and mortality. The role of surgical sutures in the etiology of surgical site infection has been the objective of discussion for decades. This study used a standardized in vitro microbiologic model to assess bacterial adherence and the antibacterial activity of a triclosan-coated polyglactin 910 (braided) suture against selected Gram-positive and Gram-negative clinical isolates that may infect surgical wounds. STUDY DESIGN: Standardized cultures (2.0 log(10) colony forming units/mL and 5.0 log(10) colony forming units/mL of three clinical strains, Staphyllococcus aureus (methicillin-resistant S aureus [MRSA]), S epidermidis (biofilm-positive) and Escherichia coli (extended-spectrum beta-lactamase [ESBL]-producer) were inoculated to triclosan-coated and noncoated polyglactin 910 sutures to evaluate comparative adherence of bacterial isolates to the antibacterial coated and noncoated surgical sutures; to assess the impact of serum proteins (bovine serum albumin) on antibacterial activity of triclosan-coated suture; and to document the duration of antibacterial activity of the triclosan-coated material. Selected suture samples were prepared for scanning electron microscopy to demonstrate bacterial adherence. RESULTS: Substantial (p < 0.01) reductions in both Gram-positive and Gram-negative bacterial adherence were observed on triclosan-coated sutures compared with noncoated material. Pretreatment of surgical sutures with 20% BSA did not diminish antibacterial activity of the triclosan-coated braided device compared with noncoated suture (p < 0.01), and antibacterial activity was documented to persist for at least 96 hours compared with controls (p < 0.01). CONCLUSIONS: The in vitro model demonstrated a considerable reduction (p < 0.01) in Gram-positive and Gram-negative bacterial adherence to a triclosan-coated braided suture, which was associated with decreased microbial viability (p < 0.001). Because bacterial contamination of suture material within a surgical wound may increase the virulence of a surgical site infection, treating the suture with triclosan provides an effective strategy for reducing perioperative surgical morbidity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jamcollsurg.2006.06.026

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 229

Metadata

Authors
Edmiston, C. E., Seabrook, G. R., Goheen, M. P., Krepel, C. J., Johnson, C. P., Lewis, B. D., Brown, K. R., & Towne, J. B.
Venue
Journal of the American College of Surgeons
Published
2006-10
Volume
203
Issue
4
Pages
481-489
ISSN
1072-7515 (ISSN-L)
OpenAlex
W1986302632
Cited by
229
References
0
FWCI
5.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bacterial Adherence to Surgical Sutures: Can Antibacterial-Coated Sutures Reduce the Risk of Microbial Contamination? https://app.cochat.ai/papers/10.1016/j.jamcollsurg.2006.06.026
The paper
Edmiston, C. E., Seabrook, G. R., Goheen, M. P., Krepel, C. J., Johnson, C. P., Lewis, B. D., Brown, K. R., & Towne, J. B. (2006). Bacterial Adherence to Surgical Sutures: Can Antibacterial-Coated Sutures Reduce the Risk of Microbial Contamination? Journal of the American College of Surgeons. https://doi.org/10.1016/j.jamcollsurg.2006.06.026

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.