Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 260

The DOI matches its Crossref record.

Intensivist Use of Hand-Carried Ultrasonography to Measure IVC Collapsibility in Estimating Intravascular Volume Status: Correlations with CVP

Stawicki, S. Peter, Braslow, Benjamin M., Panebianco, Nova L., Kirkpatrick, James N., Gracias, Vicente H., Hayden, Geoffrey E., Dean, Anthony J.·2009·Journal of the American College of Surgeons

Abstract

BACKGROUND: Volume status assessment is an important aspect of patient management in the surgical intensive care unit (SICU). Echocardiologist-performed measurement of IVC collapsibility index (IVC-CI) provides useful information about filling pressures, but is limited by its portability, cost, and availability. Intensivist-performed bedside ultrasonography (INBU) examinations have the potential to overcome these impediments. We used INBU to evaluate hemodynamic status of SICU patients, focusing on correlations between IVC-CI and CVP. STUDY DESIGN: Prospective evaluation of hemodynamic status was conducted on a convenience sample of SICU patients with a brief (3 to 10 minutes) INBU examination. INBU examinations were performed by noncardiologists after 3 hours of didactics in interpreting and acquiring two-dimensional and M-mode images, and > or =25 proctored examinations. IVC-CI measurements were compared with invasive CVP values. RESULTS: Of 124 enrolled patients, 101 had CVP catheters (55 men, mean age 58.3 years, 44.6% intubated). Of these, 18 patients had uninterpretable INBU examinations, leaving 83 patients with both CVP monitoring devices and INBU IVC evaluations. Patients in three IVC-CI ranges (<0.20, 0.20 to 0.60, and >0.60) demonstrated significant decrease in mean CVP as IVC-CI increased (p = 0.023). Although <5% of patients with IVC-CI <0.20 had CVP <7 mmHg, >40% of this group had a CVP >12 mmHg. Conversely, >60% of patients with IVC-CI >0.6 had CVP <7 mmHg. CONCLUSIONS: Measurements of IVC-CI by INBU can provide a useful guide to noninvasive volume status assessment in SICU patients. IVC-CI appears to correlate best with CVP in the setting of low (<0.20) and high (>0.60) collapsibility ranges. Additional studies are needed to confirm and expand on findings of this study.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jamcollsurg.2009.02.062

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 260

Metadata

Authors
Stawicki, S. P., Braslow, B. M., Panebianco, N. L., Kirkpatrick, J. N., Gracias, V. H., Hayden, G. E., & Dean, A. J.
Venue
Journal of the American College of Surgeons
Published
2009-07
Volume
209
Issue
1
Pages
55-61
ISSN
1072-7515 (ISSN-L)
OpenAlex
W1969419117
Cited by
260
References
0
FWCI
11.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intensivist Use of Hand-Carried Ultrasonography to Measure IVC Collapsibility in Estimating Intravascular Volume Status: Correlations with CVP. https://app.cochat.ai/papers/10.1016/j.jamcollsurg.2009.02.062
The paper
Stawicki, S. P., Braslow, B. M., Panebianco, N. L., Kirkpatrick, J. N., Gracias, V. H., Hayden, G. E., & Dean, A. J. (2009). Intensivist Use of Hand-Carried Ultrasonography to Measure IVC Collapsibility in Estimating Intravascular Volume Status: Correlations with CVP. Journal of the American College of Surgeons. https://doi.org/10.1016/j.jamcollsurg.2009.02.062

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.