De novo sequencing, peptide composition analysis, and composition-based sequencing: A new strategy employing accurate mass determination by fourier transform ion cyclotron resonance mass spectrometry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A new strategy is described for the determination of amino acid sequences of unknown peptides. Different from the well-known but often inefficient de novo sequencing approach, the new method is based on a two-step process. In the first step the amino acid composition of an unknown peptide is determined on the basis of accurate mass values of the peptide precursor ion and a small number of accurate fragment ion mass values, and, as in de novo sequencing, without employing protein database information or other pre-information. In the second step the sequence of the found amino acids of the peptide is determined by scoring the agreement between expected and observed fragment ion signals of the permuted sequences. It was found that the new approach is highly efficient if accurate mass values are available and that it easily outstrips common approaches of de novo sequencing being based on lower accuracies and detailed knowledge of fragmentation behavior. Simple permutation and calculation of all possible amino acid sequences, however, is only efficient if the composition is known or if possible compositions are at least reduced to a small list. The latter requires the highest possible instrumental mass accuracy, which is currently provided only by fourier transform ion cyclotron resonance mass spectrometry. The connection between mass accuracy and peptide composition variability is described and an example of peptide compositioning and composition-based sequencing is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484 · cited 1×
“De novo sequencing is necessary because database search procedures [23, 24 ] often fail if the proteins are modified, unknown, mutated, artificially created via, e.g., combinatorial techniques, are from unknown species or cancerous cells [25].”
Method
Cited by
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
Olsen, J. V., de Godoy, L. M. F., Li, G., Macek, B., Mortensen, P., Pesch, R., Makarov, A., Lange, O., Horning, S., & Mann, M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500030-mcp200 · Cited by 1,510
Daniel, J. F. D. S., & Rodrigues Filho, E. (2007) · Natural Product Reports · doi:10.1039/b618086h · Cited by 171
On the Proper Use of Mass Accuracy in Proteomics
Zubarev, R., & Mann, M. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m600380-mcp200 · Cited by 165
“3 ppm is required (3, 8), and this may become available in the future.”
BackgroundAutomated protein identification by tandem mass spectrometry: Issues and strategies
Hernandez, P., Müller, M., & Appel, R. D. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20068 · Cited by 164
Informatics Strategies for Large-Scale Novel Cross-Linking Analysis
Anderson, G. A., Tolic, N., Tang, X., Zheng, C., & Bruce, J. E. (2007) · Journal of Proteome Research · doi:10.1021/pr070035z · Cited by 53
“18–20 This clustering results in the observation that the phase space covered by non-peptide random masses is much greater than peptide random masses and therefore results in a lower probability that 2 randomly chosen masses will sum to match a defined precursor mass.”
Background
Metadata
- Authors
- Spengler, B.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-05-01
- Volume
- 15
- Issue
- 5
- Pages
- 703-714
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2024456313
- Cited by
- 138
- References
- 1
- FWCI
- 7.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.