The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Dynamic range of mass accuracy in LTQ orbitrap hybrid mass spectrometer
Abstract
Using a novel orbitrap mass spectrometer, the authors investigate the dynamic range over which accurate masses can be determined (extent of mass accuracy) for short duration experiments typical for LC/MS. A linear ion trap is used to selectively fill an intermediate ion storage device (C-trap) with ions of interest, following which the ensemble of ions is injected into an orbitrap mass analyzer and analyzed using image current detection and fast Fourier transformation. Using this technique, it is possible to generate ion populations with intraspectrum intensity ranges up to 10(4). All measurements (including ion accumulation and image current detection) were performed in less than 1 s at a resolving power of 30,000. It was shown that 5-ppm mass accuracy of the orbitrap mass analyzer is reached with >95% probability at a dynamic range of more than 5000, which is at least an order of magnitude higher than typical values for time-of-flight instruments. Due to the high resolving power of the orbitrap, accurate mass of an ion could be determined when the signal was reliably distinguished from noise (S/Np-p)>2...3).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Olsen, J. V., de Godoy, L. M. F., Li, G., Macek, B., Mortensen, P., Pesch, R., Makarov, A., Lange, O., Horning, S., & Mann, M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500030-mcp200 · Cited by 1,510
Self-citationElectrostatic Axially Harmonic Orbital Trapping: A High-Performance Technique of Mass Analysis
Makarov, A. (2000) · Analytical Chemistry · doi:10.1021/ac991131p · Cited by 1,009
Self-citationA two-dimensional quadrupole ion trap mass spectrometer
Schwartz, J. C., Senko, M. W., & Syka, J. E. P. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00384-7 · Cited by 796
Space charge effects in Fourier transform mass spectrometry. II. Mass calibration
Ledford, E. B., Rempel, D. L., & Gross, M. L. (1984) · Analytical Chemistry · doi:10.1021/ac00278a027 · Cited by 468
Syka, J. E. P., Marto, J. A., Bai, D. L., Horning, S., Senko, M. W., Schwartz, J. C., Ueberheide, B., Garcia, B., Busby, S., Muratore, T., et al. (2004) · Journal of Proteome Research · doi:10.1021/pr0499794 · Cited by 348
Self-citationTang, K., Page, J. S., & Smith, R. D. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.04.034 · Cited by 262
Theory of space-charge shift of ion cyclotron resonance frequencies
Jeffries, J. B., Barlow, S. E., & Dunn, G. H. (1983) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(83)85016-2 · Cited by 218
Time‐of‐flight mass spectrometry
Cotter, R. J. (2005) · Encyclopedia of Genetics, Genomics, Proteomics and Bioinformatics · doi:10.1002/047001153x.g301302 · Cited by 211
Routine Part-per-Million Mass Accuracy for High- Mass Ions: Space-Charge Effects in MALDI FT-ICR
Easterling, M. L., Mize, T. H., & Amster, I. J. (1998) · Analytical Chemistry · doi:10.1021/ac980690d · Cited by 150
Limbach, P. A., Grosshans, P. B., & Marshall, A. G. (1993) · Analytical Chemistry · doi:10.1021/ac00050a008 · Cited by 95
Mass measurement errors caused by “local” frequency perturbations in FTICR mass spectrometry
Masselon, C., Tolmachev, A. V., Anderson, G., Harkewicz, R., & Smith, R. D. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(01)00333-6 · Cited by 82
Chen, L., Cottrell, C. E., & Marshall, A. G. (1986) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(86)80025-9 · Cited by 74
Fourier transform ion cyclotron resonance mass spectrometry
Marshall, A. G., & Verdun, F. R. (1990) · Elsevier eBooks · doi:10.1016/b978-0-444-87360-6.50012-1 · Cited by 69
Blom, K. F. (2001) · Analytical Chemistry · doi:10.1021/ac001064v · Cited by 61
Verdun, F. R., Giancaspro, C., & Marshall, A. G. (1988) · Applied Spectroscopy · doi:10.1366/0003702884429094 · Cited by 42
Cited by
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
Michalski, A., Damoc, E., Hauschild, J.-P., Lange, O., Wieghaus, A., Makarov, A., Nagaraj, N., Cox, J., Mann, M., & Horning, S. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.011015 · Cited by 832
Self-citationZubarev, R. A., & Makarov, A. (2013) · Analytical Chemistry · doi:10.1021/ac4001223 · Cited by 658
Self-citationOrbitrap mass spectrometry: Instrumentation, ion motion and applications
Perry, R. H., Cooks, R. G., & Noll, R. J. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20186 · Cited by 514
A dual pressure linear ion trap orbitrap instrument with very high sequencing speed
Olsen, J. V., Schwartz, J. C., Griep-Raming, J., Nielsen, M. L., Damoc, E., Denisov, E., Lange, O., Remes, P., Taylor, D., Splendore, M., et al. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900375-mcp200 · Cited by 464
Self-citation
Metadata
- Authors
- Makarov, A., Denisov, E., Lange, O., & Horning, S.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-07-01
- Volume
- 17
- Issue
- 7
- Pages
- 977-982
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2027603999
- Cited by
- 431
- References
- 15
- FWCI
- 12.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.