Relative importance of basicity in the gas phase and in solution for determining selectivity in electrospray ionization mass spectrometry
Open accessThe DOI matches its Crossref record.
Abstract
Electrospray ionization mass spectrometry is a critically important technique for the determination of small molecules, but its application for this purpose is complicated by its selectivity. For positive ion ESI-MS analysis of basic analytes, several investigators have pointed to the importance of analyte basicity as a source of selectivity. Currently, however, it is not known whether basicity in the gas phase or in solution is ultimately most important in determining responsiveness. The objective of these studies was to investigate the relative importance of basicity in solution and in the gas phase as factors that predict selectivity in positive ion ESI-MS analysis. ESI-MS response was compared for a diverse series of protonatable analytes in two different solvents, neat methanol and methanol with 0.5% acetic acid. A correlation was observed between analyte pK(b) and electrospray response. However, the response for the analytes with very high pK(b) values was significantly higher than would be expected based on concentration of the protonated form or the analyte in solution, and this higher response did not appear to result from gas-phase proton transfer reactions. Although all of the analytes investigated had higher gas-phase basicities than the solvent, their relative responses were not dictated by gas-phase basicity. Higher response was observed for all of the analytes studied in acidified methanol compared with neat methanol, and this higher response was most pronounced for weakly basic analytes. These findings support the use of analyte pK(b) for rational method development in ESI-MS analysis of small molecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrospray Ionization Efficiency Scale of Organic Compounds
Oss, M., Kruve, A., Herodes, K., & Leito, I. (2010) · Analytical Chemistry · doi:10.1021/ac902856t · Cited by 309
NORMAN guidance on suspect and non-target screening in environmental monitoring
Hollender, J., Schymanski, E. L., Ahrens, L., Alygizakis, N., Béen, F., Bijlsma, L., Brunner, A. M., Celma, A., Fildier, A., Fu, Q., et al. (2023) · Environmental Sciences Europe · doi:10.1186/s12302-023-00779-4 · Cited by 278
Hug, C., Ulrich, N., Schulze, T., Brack, W., & Krauss, M. (2014) · Environmental Pollution · doi:10.1016/j.envpol.2013.07.048 · Cited by 252
Kammeijer, G. S. M., Kohler, I., Jansen, B. C., Hensbergen, P. J., Mayboroda, O. A., Falck, D., & Wuhrer, M. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00479 · Cited by 74
van Winden, L. J., Kok, M., Acda, M., Dezentje, V., Linn, S., Shi, R.-Z., & van Rossum, H. H. (2021) · Journal of Chromatography B · doi:10.1016/j.jchromb.2021.122563 · Cited by 23
Metadata
- Authors
- Ehrmann, B. M., Henriksen, T., & Cech, N. B.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-05-01
- Volume
- 19
- Issue
- 5
- Pages
- 719-728
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2141400573
- Cited by
- 102
- References
- 0
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.