Peptide and protein quantification using iTRAQ with electron transfer dissociation
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Electron transfer dissociation (ETD) has become increasingly used in proteomic analyses due to its complementarity to collision-activated dissociation (CAD) and its ability to sequence peptides with post-translation modifications (PTMs). It was previously unknown, however, whether ETD would be compatible with a commonly employed quantification technique, isobaric tags for relative and absolute quantification (iTRAQ), since the fragmentation mechanisms and pathways of ETD differ significantly from CAD. We demonstrate here that ETD of iTRAQ labeled peptides produces c- and z-type fragment ions as well as reporter ions that are unique from those produced by CAD. Exact molecular formulas of product ions were determined by ETD fragmentation of iTRAQ-labeled synthetic peptides followed by high mass accuracy orbitrap mass analysis. These experiments revealed that ETD cleavage of the N-C(alpha) bond of the iTRAQ tag results in fragment ions that could be used for quantification. Synthetic peptide work demonstrates that these fragment ions provide up to three channels of quantification and that the quality is similar to that provided by beam-type CAD. Protein standards were used to evaluate peptide and protein quantification of iTRAQ labeling in conjunction with ETD, beam-type CAD, and pulsed Q dissociation (PQD) on a hybrid ion trap-orbitrap mass spectrometer. For reporter ion intensities above a certain threshold all three strategies provided reliable peptide quantification (average error <10%). Approximately 36%, 8%, and 16% of scans identified fall below this threshold for ETD, HCD, and PQD, respectively. At the protein level, average errors were 2.3%, 1.7%, and 3.6% for ETD, HCD, and PQD, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ross, P. L., Huang, Y. N., Marchese, J. N., Williamson, B., Parker, K., Hattan, S., Khainovski, N., Pillai, S., Dey, S., Daniels, S., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400129-mcp200 · Cited by 4,401 · cited 1×
“This compares favorably with the 6% error originally reported for protein level quantification using iTRAQ labeling and beam-type CAD fragmentation [13].”
ResultPeptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Self-citationMass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572
Metabolic Labeling of Mammalian Organisms with Stable Isotopes for Quantitative Proteomic Analysis
Wu, C. C., MacCoss, M. J., Howell, K. E., Matthews, D. E., & Yates, J. R. (2004) · Analytical Chemistry · doi:10.1021/ac049208j · Cited by 386
Cited by
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
“Emerging reports show applicability of ETD for peptide (32) and protein (179) quantification with an ETD-enabled LTQ-Orbitrap.”
Quantitative mass spectrometry in proteomics: critical review update from 2007 to the present
Bantscheff, M., Lemeer, S., Savitski, M. M., & Kuster, B. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6203-4 · Cited by 801
Increasing the Multiplexing Capacity of TMTs Using Reporter Ion Isotopologues with Isobaric Masses
McAlister, G. C., Huttlin, E. L., Haas, W., Ting, L., Jedrychowski, M. P., Rogers, J. C., Kuhn, K., Pike, I., Grothe, R. A., Blethrow, J. D., et al. (2012) · Analytical Chemistry · doi:10.1021/ac301572t · Cited by 605
Fragmentation of Integral Membrane Proteins in the Gas Phase
Skinner, O. S., Catherman, A. D., Early, B. P., Thomas, P. M., Compton, P. D., & Kelleher, N. L. (2014) · Analytical Chemistry · doi:10.1021/ac500864w · Cited by 29
Metadata
- Authors
- Phanstiel, D., Zhang, Y., Marto, J. A., & Coon, J. J.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-09-01
- Volume
- 19
- Issue
- 9
- Pages
- 1255-1262
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2127876423
- Cited by
- 57
- References
- 4
- FWCI
- 3.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Peptide and protein quantification using iTRAQ with electron transfer dissociation. https://app.cochat.ai/papers/10.1016/j.jasms.2008.05.023
- The paper
- Phanstiel, D., Zhang, Y., Marto, J. A., & Coon, J. J. (2008). Peptide and protein quantification using iTRAQ with electron transfer dissociation. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/j.jasms.2008.05.023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.