The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Quantitative-qualitative data acquisition using a benchtop orbitrap mass spectrometer
Abstract
Current approaches to discovery-stage drug metabolism studies (pharmacokinetics, microsomal stability, etc.) typically use triple-quadrupole-based approaches for quantitative analysis. This necessitates the optimization of parameters such as Q1 and Q3 m/z values, collision energy, and interface voltages. These studies detect only the specified compound and information about other components, such as metabolites, is lost. The ability to perform full-scan acquisition for quantitative analysis would eliminate the need for compound optimization while enabling the detection of metabolites and other non-drug-related endogenous components. Such an instrument would have to provide sensitivity, selectivity, dynamic range, and scan speed suitable for discovery-stage quantitative studies. In this study, a prototype benchtop Orbitrap-based mass analyzer was used to collect both quantitative and qualitative data from human microsomal incubation samples as well as rat plasma from pharmacokinetic studies. Instrumental parameters such as scan speed, resolution, and mass accuracy are discussed in relation to the requirements for a quantitative-qualitative workflow. The ability to perform highly selective quantitative analysis while simultaneously characterizing metabolites from both in vitro and in vivo studies is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Can the pharmaceutical industry reduce attrition rates?
Kola, I., & Landis, J. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1470 · Cited by 4,167
The State of Innovation in Drug Development
Kola, I. (2008) · Clinical Pharmacology & Therapeutics · doi:10.1038/sj.clpt.6100479 · Cited by 276
Cited by
Michalski, A., Damoc, E., Hauschild, J.-P., Lange, O., Wieghaus, A., Makarov, A., Nagaraj, N., Cox, J., Mann, M., & Horning, S. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.011015 · Cited by 832
Zubarev, R. A., & Makarov, A. (2013) · Analytical Chemistry · doi:10.1021/ac4001223 · Cited by 658
Lu, W., Clasquin, M. F., Melamud, E., Amador-Noguez, D., Caudy, A. A., & Rabinowitz, J. D. (2010) · Analytical Chemistry · doi:10.1021/ac902837x · Cited by 502
Metadata
- Authors
- Bateman, K. P., Kellmann, M., Muenster, H., Papp, R., & Taylor, L.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-03-06
- Volume
- 20
- Issue
- 8
- Pages
- 1441-1450
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2025092292
- Cited by
- 192
- References
- 2
- FWCI
- 9.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative-qualitative data acquisition using a benchtop orbitrap mass spectrometer. https://app.cochat.ai/papers/10.1016/j.jasms.2009.03.002
- The paper
- Bateman, K. P., Kellmann, M., Muenster, H., Papp, R., & Taylor, L. (2009). Quantitative-qualitative data acquisition using a benchtop orbitrap mass spectrometer. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/j.jasms.2009.03.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.