What does the future hold for top down mass spectrometry?
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Mass spectrometry (MS) research has revolutionized modern biological and biomedical fields. At the heart of the majority of mass spectrometry experiments is the use of Bottom Up mass spectrometry methods where proteins are first proteolyzed into smaller fragments before MS interrogation. The advent of electron capture dissociation and, more recently, electron-transfer dissociation, however, has allowed Top Down (analysis of intact proteins) or middle down (analysis of large polypeptides) mass spectrometry to both experience large increases in development, growth, and overall usage. Nevertheless, for high-throughput large-scale proteomic studies, Bottom Up mass spectrometry has easily dominated the field. As Top Down mass spectrometry methodology and technology continue to develop, will it genuinely be able to compete with Bottom Up mass spectrometry for whole proteome analysis? Discussed here are the current approaches, applications, issues, and future view of high-throughput Top Down mass spectrometry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Universal sample preparation method for proteome analysis
Wiśniewski, J. R., Zougman, A., Nagaraj, N., & Mann, M. (2009) · Nature Methods · doi:10.1038/nmeth.1322 · Cited by 8,352
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370 · cited 1×
“this all occurs in a ion trap mass spectrometer [56].”
BackgroundElectron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Comprehensive mass-spectrometry-based proteome quantification of haploid versus diploid yeast
de Godoy, L. M. F., Olsen, J. V., Cox, J., Nielsen, M. L., Hubner, N. C., Fröhlich, F., Walther, T. C., & Mann, M. (2008) · Nature · doi:10.1038/nature07341 · Cited by 873
Decoding protein modifications using top-down mass spectrometry
Siuti, N., & Kelleher, N. L. (2007) · Nature Methods · doi:10.1038/nmeth1097 · Cited by 503
Protein identification using sequential ion/ion reactions and tandem mass spectrometry
Coon, J. J., Ueberheide, B., Syka, J. E. P., Dryhurst, D. D., Ausio, J., Shabanowitz, J., & Hunt, D. F. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503189102 · Cited by 373
Extending Top-Down Mass Spectrometry to Proteins with Masses Greater Than 200 Kilodaltons
Han, X., Jin, M., Breuker, K., & McLafferty, F. W. (2006) · Science · doi:10.1126/science.1128868 · Cited by 328
Processing Complex Mixtures of Intact Proteins for Direct Analysis by Mass Spectrometry
Meng, F., Cargile, B. J., Patrie, S. M., Johnson, J. R., McLoughlin, S. M., & Kelleher, N. L. (2002) · Analytical Chemistry · doi:10.1021/ac020049i · Cited by 183
Cited by
Nesvizhskii, A. I. (2010) · Journal of Proteomics · doi:10.1016/j.jprot.2010.08.009 · Cited by 536
Zhang, Z., Wu, S., Stenoien, D. L., & Paša-Tolić, L. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020216 · Cited by 323
Protein Identification Using Top-Down Spectra
Liu, X., Sirotkin, Y., Shen, Y., Anderson, G., Tsai, Y. S., Ting, Y. S., Goodlett, D. R., Smith, R. D., Bafna, V., & Pevzner, P. A. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.008524 · Cited by 153
“…focuses on analyzing intact proteins and large peptides (1–10) and has advantages in localizing multiple post-translational modifications (PTMs) 1 in a coordinated fashion ( e.g. combinatorial PTM code) and identifying multiple protein species ( e.g. proteolytically processed protein species) (11).”
BackgroundYang, Y., Liu, F., Franc, V., Halim, L. A., Schellekens, H., & Heck, A. J. R. (2016) · Nature Communications · doi:10.1038/ncomms13397 · Cited by 152
Toward an Optimized Workflow for Middle-Down Proteomics
Cristobal, A., Marino, F., Post, H., van den Toorn, H. W. P., Mohammed, S., & Heck, A. J. R. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03756 · Cited by 130
Metadata
- Authors
- Garcia, B. A.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-02-01
- Volume
- 21
- Issue
- 2
- Pages
- 193-202
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W1981132421
- Cited by
- 124
- References
- 8
- FWCI
- 3.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.