A mixed-methods evaluation framework for electronic health records usability studies
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Background: Poor EHR design adds further challenges, especially in the areas of order entry and information visualization, with a net effect of increased rates of incidents, accidents, and mortality in ICU settings. Objective: The purpose of the study was to propose a novel, mixed-methods framework to understand EHR-related information overload by identifying and characterizing areas of suboptimal usability and clinician frustration within a vendor-based, provider-facing EHR interface. Methods: A mixed-methods, live observational usability study was conducted at a single, large, tertiary academic medical center in the Southeastern US utilizing a commercial, vendor based EHR. Physicians were asked to complete usability patient cases, provide responses to three surveys, and participant in a semi-structured interview. Results: Of the 25 enrolled ICU physician participants, there were 5(20%) attending physicians, 9 (36%) fellows, and 11 (44%) residents; 52% of participants were females. A significant negative correlation was found between EHR usability and ease of use with frustration, such that as usability and ease of use increased, frustration levels decreased (p=.00 and p=. 01 respectively). Performance was negatively correlated with complexity and inconsistency in the interface design, where the higher degrees of complexity or inconsistency in the EHR associated to lower perceived performance of physicians (p=.03 and p=.00 respectively). Discussion: Physicians remain frustrated with the EHR due to difficulty in finding patient information. EHR usability remains a critical challenge in healthcare, with implications for medical errors, patient safety, and clinician burnout. There is a need for scientific findings on current information needs and ways to improve EHR-related information overload.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SUS: A 'Quick and Dirty' Usability Scale
(1996) · Usability Evaluation In Industry · doi:10.1201/9781498710411-35 · Cited by 8,989
A mathematical model of the finding of usability problems
Nielsen, J., & Landauer, T. K. (1993) · Proceedings of the SIGCHI conference on Human factors in computing systems - CHI '93 · doi:10.1145/169059.169166 · Cited by 1,961
Shanafelt, T. D., Dyrbye, L. N., Sinsky, C., Hasan, O., Satele, D., Sloan, J., & West, C. P. (2016) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2016.05.007 · Cited by 1,086 · cited 1×
“Prior work has examined the relationship between EHR use and clerical burden, demonstrating low provider satisfaction and higher risk of burnout [27].”
BackgroundRatwani, R. M., Benda, N. C., Hettinger, A. Z., & Fairbanks, R. J. (2015) · JAMA · doi:10.1001/jama.2015.8372 · Cited by 91 · cited 1×
“While vigorous usability testing has penetrated other industries such as aviation and transportation, recent studies have shown that the use of user-centered design principles among EHR vendors has been more limited [10].”
BackgroundClinical decision support systems in the pediatric intensive care unit*
Mack, E. H., Wheeler, D. S., & Embi, P. J. (2009) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0b013e3181936b23 · Cited by 76
Asan, O., & Yang, Y. (2015) · JMIR Human Factors · doi:10.2196/humanfactors.4062 · Cited by 66 · cited 1×
“Prior EHR usability work has also employed eye-tracking technology [23] as well as simulation-based testing [24, 25], but our study will provide the largest dataset with regard to physicians in critical care settings where the stakes are quite high.”
MethodMazur, L. M., Mosaly, P. R., Moore, C., Comitz, E., Yu, F., Falchook, A. D., Eblan, M. J., Hoyle, L. M., Tracton, G., Chera, B. S., et al. (2016) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocw016 · Cited by 45 · cited 1×
“Prior EHR usability work has also employed eye-tracking technology [23] as well as simulation-based testing [24, 25], but our study will provide the largest dataset with regard to physicians in critical care settings where the stakes are quite high.”
Method
Cited by
Association of electronic health record use with physician fatigue and efficiency
Khairat, S., Coleman, C., Ottmar, P., Jayachander, D. I., Bice, T., & Carson, S. S. (2020) · JAMA Network Open · doi:10.1001/jamanetworkopen.2020.7385 · Cited by 118
Self-citationBridging the “last mile” gap between AI implementation and operation: “data awareness” that matters
Cabitza, F., Campagner, A., & Balsano, C. (2020) · Annals of Translational Medicine · doi:10.21037/atm.2020.03.63 · Cited by 113
“The concerns regarding the quality of the electronic data collection tools—their low usability and poor HCI (see Figure 2)—have several implications, including for medical errors, patient safety, and clinician burnout (36).”
BackgroundWronikowska, M. W., Malycha, J., Morgan, L. J., Westgate, V., Petrinic, T., Young, J. D., & Watkinson, P. J. (2021) · Journal of Evaluation in Clinical Practice · doi:10.1111/jep.13582 · Cited by 59
“The purpose of interviews following the user trial (prestructured, 71 posttest, 38 semi-structured 39,70,72,42,43,74 [one called in-depth debriefing semi-structured interview 69 ]) was mainly gathering information about missing data, system's weaknesses, opportunities for improvements, and users'…”
Metadata
- Authors
- Khairat, S., Coleman, C., Newlin, T., Rand, V., Ottmar, P., Bice, T., & Carson, S. S.
- Venue
- Journal of Biomedical Informatics
- Publisher
- Elsevier BV
- Published
- 2019-06
- Volume
- 94
- Pages
- 103175
- ISSN
- 1532-0464 (ISSN-L)
- OpenAlex
- W2936630858
- Cited by
- 50
- References
- 7
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A mixed-methods evaluation framework for electronic health records usability studies. https://app.cochat.ai/papers/10.1016/j.jbi.2019.103175
- The paper
- Khairat, S., Coleman, C., Newlin, T., Rand, V., Ottmar, P., Bice, T., & Carson, S. S. (2019). A mixed-methods evaluation framework for electronic health records usability studies. Journal of Biomedical Informatics. https://doi.org/10.1016/j.jbi.2019.103175
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.