Strains and stresses in sub-dermal tissues of the buttocks are greater in paraplegics than in healthy during sitting
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Berecek, K. H. (1975) · Nursing Clinics of North America · doi:10.1016/s0029-6465(22)00465-0 · Cited by 411
Castro, M. J., Apple Jr, D. F., Hillegass, E. A., & Dudley, G. A. (1999) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/s004210050606 · Cited by 383
Etiologic factors in pressure sores: an experimental model.
Daniel, R. K., Priest, D., & Wheatley, D. (1981) · PubMed · Cited by 370
Influence of complete spinal cord injury on skeletal muscle within 6 mo of injury
Castro, M. J., Apple, D. F., Staron, R. S., Campos, G. E. R., & Dudley, G. A. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.1.350 · Cited by 338
Giangregorio, L., & McCartney, N. (2006) · The Journal of Spinal Cord Medicine · doi:10.1080/10790268.2006.11753898 · Cited by 335
Linder-Ganz, E., Shabshin, N., Itzchak, Y., & Gefen, A. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.06.020 · Cited by 333 · cited 3×
“Our present goals were therefore to (i) determine strain/stress magnitudes and distributions in sub-dermal tissues under the IT of paraplegics during sitting and lying and (ii) compare the paraplegic data with those obtained previously from healthy subjects using the same MRI-FE setup (Linder-Ganz et al., 2007).”
BackgroundMethodResultSelf-citationOomens, C. W. J., Bressers, O. F. J. T., Bosboom, E. M., Bouten, C. V. C., & Bader, D. L. (2003) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/1025584031000121034 · Cited by 215 · cited 2×
“Our data of peak principal stresses in muscles agrees with previous FE modeling of the seated buttocks, where stress values in the range of 20–200 kPa were reported (Ragan et al., 2002; Oomens et al., 2003; Verver et al., 2004).”
BackgroundResultLinder‐Ganz, E., & Gefen, A. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00888.2003 · Cited by 210 · cited 1×
“Animal models indicated that the onset of a DTI involves changes in muscle stiffness which become more substantial with the progressive death of muscle cells (Linder-Ganz and Gefen, 2004; Gefen et al., 2005).”
BackgroundSelf-citationDifferential Response of Skin and Muscle in the Experimental Production of Pressure Sores
Nola, G. T., & Vistnes, L. M. (1980) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-198011000-00008 · Cited by 205
Gawlitta, D., Li, W., Oomens, C. W. J., Baaijens, F. P. T., Bader, D. L., & Bouten, C. V. C. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9222-5 · Cited by 184 · cited 1×
“, 2005) and recently, muscle cell cultures and tissue-engineered constructs (Bouten et al., 2001; Gawlitta et al., 2007).”
BackgroundA Finite Element Model of the Human Buttocks for Prediction of Seat Pressure Distributions
Verver, M. M., van Hoof, J., Oomens, C. W. J., Wismans, J. S. H. M., & Baaijens, F. F. (2004) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840410001727832 · Cited by 150 · cited 2×
“Our data of peak principal stresses in muscles agrees with previous FE modeling of the seated buttocks, where stress values in the range of 20–200 kPa were reported (Ragan et al., 2002; Oomens et al., 2003; Verver et al., 2004).”
BackgroundResultSalcido, R., Donofrio, J. C., Fisher, S. B., LeGrand, E. K., Dickey, K. M., Carney, J. M., Schosser, R., & Liang, R. (1994) · PubMed · Cited by 118
Compression-induced deep tissue injury examined with magnetic resonance imaging and histology
Stekelenburg, A. A., Oomens, C. W. J., Strijkers, G. J., et al. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00889.2005 · Cited by 115
Veress, A. I., Gullberg, G. T., & Weiss, J. A. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.2073677 · Cited by 115 · cited 1×
“(2007) provides the strain/stress distributions in soft tissues modeled as non-linear continuum materials, by FE processing of MR images of the unloaded and loaded organ, without the need for markers or MR tags similar to hyperelastic warping (Veress et al., 2005).”
BackgroundCruse, J. M., Lewis, R. E., Dilioglou, S., Roe, D. L., Wallace, W. F., & Chen, R. S. (2000) · Journal of Spinal Cord Medicine · doi:10.1080/10790268.2000.11753520 · Cited by 84
Bone adaptation to altered loading after spinal cord injury: a study of bone and muscle strength.
Rittweger, J., Gerrits, K. H. L., Altenburg, T. M., Reeves, N. D., Maganaris, C. N., & HAAN, A. D. (2006) · VU Research Portal · Cited by 71
Bosboom, E. M., Bouten, C. V. C., Oomens, C. W. J., van Straaten, H. W. M., Baaijens, F. F., & Kuipers, H. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00034-0 · Cited by 68
Estimation of geometric properties of cortical bone in spinal cord injury
de Bruin, E. D., Herzog, R., Rozendal, R. H., Michel, D., & Stüssi, E. (2000) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(00)90133-3 · Cited by 37 · cited 1×
“The pathoanatomy of the lower body in SCI has been documented in numerous studies (see Giangregorio and McCartney (2006) for a review), and includes loss of muscle mass (Castro et al.”
Background
Metadata
- Authors
- Linder-Ganz, E., Shabshin, N., Itzchak, Y., Yizhar, Z., Siev-Ner, I., & Gefen, A.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2008
- Volume
- 41
- Issue
- 3
- Pages
- 567-580
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2044369439
- Cited by
- 205
- References
- 18
- FWCI
- 43.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.