Viscoelastic properties of passive skeletal muscle in compression: Stress-relaxation behaviour and constitutive modelling
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Biomechanics: Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138285 · Cited by 2,769 · cited 3×
“In this paper, it is hypothesised that this model can be extended using the quasi-linear viscoelasticity framework (Fung, 1993) formulated with Prony series to predict the large strain three-dimensional relaxation behaviour of muscle tissue in compression.”
InfluentialThe Phenomenological Theory of Linear Viscoelastic Behavior: An Introduction
Tschoegl, N. W. (1989) · CERN Document Server (European Organization for Nuclear Research) · Cited by 662
Dynamic response of bone and muscle tissue.
McElhaney, J. H. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.4.1231 · Cited by 509 · cited 2×
“However, previous research clearly shows that muscle elastic behaviour is nonlinear (Grieve and Armstrong, 1988; McElhaney, 1966 Van Loocke et al., 2006; Van Sligtenhorst et al., 2006).”
BackgroundLinder-Ganz, E., Shabshin, N., Itzchak, Y., & Gefen, A. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.06.020 · Cited by 333 · cited 1×
“…in compression are used in impact biomechanics (Forbes et al., 2005; van Rooij et al., 2003; Verver et al., 2004), in rehabilitation engineering (Krouskop et al., 1987; Linder-Ganz et al., 2007; Mak et al., 2001) and for simulation of surgical procedures (Guccione et al., 2001; Keeve et al., 1998).”
Ligament material behavior is nonlinear, viscoelastic and rate-independent under shear loading
Weiss, J. A., Gardiner, J. C., & Bonifasi-Lista, C. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00041-6 · Cited by 210 · cited 1×
“It can therefore be expected to display time and history-dependent behaviour resulting from interactions between these constituents as shown for soft tissues with similar structure such as ligaments and tendons (Abramowitch et al., 2004; Kwan et al., 1993; Weiss et al., 2002).”
BackgroundA validated model of passive muscle in compression
Van Loocke, M., Lyons, C. G., & Simms, C. K. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.10.016 · Cited by 203 · cited 12×
“A transversely isotropic, SYM model was previously developed to represent skeletal muscle nonlinear elastic properties (Van Loocke et al., 2006)”
BackgroundMethodInfluentialSelf-citationPassive transverse mechanical properties of skeletal muscle under in vivo compression
Bosboom, E. M. H., Hesselink, M. K. C., Oomens, C. W. J., Bouten, C. V. C., Drost, M. R., & Baaijens, F. P. T. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00083-5 · Cited by 179 · cited 2×
“As pointed out previously (Palevski et al., 2006), there is little published data on skeletal muscle viscoelastic properties (Best et al., 1994 in tension; Bosboom et al., 2001a, b in compression).”
BackgroundOn the viscoelastic properties of the anteromedial bundle of the anterior cruciate ligament
Kwan, M. K., Lin, T. H.-C., & Woo, S. L.-Y. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90008-3 · Cited by 171 · cited 1×
“It can therefore be expected to display time and history-dependent behaviour resulting from interactions between these constituents as shown for soft tissues with similar structure such as ligaments and tendons (Abramowitch et al., 2004; Kwan et al., 1993; Weiss et al., 2002).”
BackgroundObjective assessment of limb tissue elasticity: development of a manual indentation procedure.
Zheng, Y., Mak, A. F. T., & Lue, B. (1999) · PubMed · Cited by 169
A Finite Element Model of the Human Buttocks for Prediction of Seat Pressure Distributions
Verver, M. M., van Hoof, J., Oomens, C. W. J., Wismans, J. S. H. M., & Baaijens, F. F. (2004) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840410001727832 · Cited by 150 · cited 1×
“Finite element models of the human body in compression are used in impact biomechanics (Forbes et al., 2005; van Rooij et al., 2003; Verver et al., 2004), in rehabilitation engineering (Krouskop et al., 1987; Linder-Ganz et al., 2007; Mak et al., 2001) and for simulation of surgical procedures…”
MethodDynamic and quasi-static compressive response of porcine muscle
Song, B., Chen, W., Ge, Y., & Weerasooriya, T. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.02.001 · Cited by 147 · cited 1×
“McElhaney (1966), Van Sligtenhorst et al. (2006) and Song et al. (2007) observed that muscle compressive response is nonlinear and strongly strain-rate sensitive.”
BackgroundSligtenhorst, C. R. V., Cronin, D. S., & Brodland, G. W. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.015 · Cited by 125
Palevski, A., Glaich, I., Portnoy, S., Linder‐Ganz, E., & Gefen, A. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2264395 · Cited by 113 · cited 5×
“A value of 523 Pa was obtained, which is in good agreement with the data from Palevski et al. (2006).”
BackgroundMethodResultInfluentialAbramowitch, S. D., Woo, S. L., Clineff, T. D., & Debski, R. E. (2004) · Annals of Biomedical Engineering · doi:10.1023/b:abme.0000017539.85245.6a · Cited by 88 · cited 1×
“It can therefore be expected to display time and history-dependent behaviour resulting from interactions between these constituents as shown for soft tissues with similar structure such as ligaments and tendons (Abramowitch et al., 2004; Kwan et al., 1993; Weiss et al., 2002).”
BackgroundIn vivo indentation of lower extremity limb soft tissues
Silverthorn, M. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788464 · Cited by 56 · cited 2×
“Silver-Thorn (1999) reported that limb bulk soft tissues undergo substantial relaxation after indenting the tissue at 5 mm s (cid:2) 1 , 95% relaxation was observed on average, most of it within 5 s.”
BackgroundGuccione, J. M., Moonly, S. M., Wallace, A. W., & Ratcliffe, M. B. (2001) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2001.114939 · Cited by 45 · cited 1×
“…in compression are used in impact biomechanics (Forbes et al., 2005; van Rooij et al., 2003; Verver et al., 2004), in rehabilitation engineering (Krouskop et al., 1987; Linder-Ganz et al., 2007; Mak et al., 2001) and for simulation of surgical procedures (Guccione et al., 2001; Keeve et al., 1998).”
van Rooij, L., Bours, R., van Hoof, J., Mihm, J. J., Ridella, S. A., Bass, C. R., & Crandall, J. (2003) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2003-22-0004 · Cited by 24 · cited 1×
“Finite element models of the human body in compression are used in impact biomechanics (Forbes et al., 2005; van Rooij et al., 2003; Verver et al., 2004), in rehabilitation engineering (Krouskop et al., 1987; Linder-Ganz et al., 2007; Mak et al., 2001) and for simulation of surgical procedures…”
MethodNumerical Human Model to Predict Side Impact Thoracic Trauma
Forbes, P. A., Cronin, D. S., Deng, Y., & Boismenu, M. (2005) · Springer eBooks · doi:10.1007/1-4020-3796-1_45 · Cited by 15 · cited 1×
“Finite element models of the human body in compression are used in impact biomechanics (Forbes et al., 2005; van Rooij et al., 2003; Verver et al., 2004), in rehabilitation engineering (Krouskop et al., 1987; Linder-Ganz et al., 2007; Mak et al., 2001) and for simulation of surgical procedures…”
Method
Cited by
Transversely isotropic tensile material properties of skeletal muscle tissue
Morrow, D. A., Haut Donahue, T. L., Odegard, G. M., & Kaufman, K. R. (2010) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2009.03.004 · Cited by 238
“Comparisons with studies of skeletal muscle under compression (Van Loocke et al., 2006, 2008) suggest that skeletal muscle tissue is a bimodularmaterial.”
BackgroundMechanical Mapping of Spinal Cord Growth and Repair in Living Zebrafish Larvae by Brillouin Imaging
Schlüßler, R., Möllmert, S., Abuhattum, S., Cojoc, G., Müller, P., Kim, K., Möckel, C., Zimmermann, C., Czarske, J., & Guck, J. (2018) · Biophysical Journal · doi:10.1016/j.bpj.2018.07.027 · Cited by 170
Koo, T. K., Cohen, J. H., & Zheng, Y. (2011) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2011.05.009 · Cited by 16
Metadata
- Authors
- Van Loocke, M., Lyons, C. G., & Simms, C. K.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2008-01
- Volume
- 41
- Issue
- 7
- Pages
- 1555-1566
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W1970219880
- Cited by
- 228
- References
- 19
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.