The DOI matches its Crossref record.
Non-invasive assessment of soft-tissue artifact and its effect on knee joint kinematics during functional activity
Open accessAbstract
The soft-tissue interface between skin-mounted markers and the underlying bones poses a major limitation to accurate, non-invasive measurement of joint kinematics. The aim of this study was twofold: first, to quantify lower limb soft-tissue artifact in young healthy subjects during functional activity; and second, to determine the effect of soft-tissue artifact on the calculation of knee joint kinematics. Subject-specific bone models generated from magnetic resonance imaging (MRI) were used in conjunction with X-ray images obtained from single-plane fluoroscopy to determine three-dimensional knee joint kinematics for four separate tasks: open-chain knee flexion, hip axial rotation, level walking, and a step-up. Knee joint kinematics was derived using the anatomical frames from the MRI-based, 3D bone models together with the data from video motion capture and X-ray fluoroscopy. Soft-tissue artifact was defined as the degree of movement of each marker in the anteroposterior, proximodistal and mediolateral directions of the corresponding anatomical frame. A number of different skin-marker clusters (total of 180) were used to calculate knee joint rotations, and the results were compared against those obtained from fluoroscopy. Although a consistent pattern of soft-tissue artifact was found for each task across all subjects, the magnitudes of soft-tissue artifact were subject-, task- and location-dependent. Soft-tissue artifact for the thigh markers was substantially greater than that for the shank markers. Markers positioned in the vicinity of the knee joint showed considerable movement, with root mean square errors as high as 29.3mm. The maximum root mean square errors for calculating knee joint rotations occurred for the open-chain knee flexion task and were 24.3 degrees , 17.8 degrees and 14.5 degrees for flexion, internal-external rotation and abduction-adduction, respectively. The present results on soft-tissue artifact, based on fluoroscopic measurements in healthy adult subjects, may be helpful in developing location- and direction-specific weighting factors for use in global optimization algorithms aimed at minimizing the effects of soft-tissue artifact on calculations of knee joint rotations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dorn, T. W., Schache, A. G., & Pandy, M. G. (2012) · Journal of Experimental Biology · doi:10.1242/jeb.064527 · Cited by 535
Self-citationEffect of Running Speed on Lower Limb Joint Kinetics
SCHACHE, A. G., BLANCH, P. D., DORN, T. W., BROWN, N. A. T., ROSEMOND, D., & PANDY, M. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182084929 · Cited by 361
Self-citationMuscle and Joint Function in Human Locomotion
Pandy, M. G., & Andriacchi, T. P. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105259 · Cited by 325
Self-citationA new approach to measure functional stability of the knee based on changes in knee axis orientation
Grip, H., & Häger, C. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.12.015 · Cited by 46
Buchman-Pearle, J. M., & Acker, S. M. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110659 · Cited by 10
Metadata
- Authors
- Akbarshahi, M., Schache, A. G., Fernandez, J. W., Baker, R., Banks, S., & Pandy, M. G.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2010-05
- Volume
- 43
- Issue
- 7
- Pages
- 1292-1301
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2162836731
- Cited by
- 232
- References
- 0
- FWCI
- 12.73
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-invasive assessment of soft-tissue artifact and its effect on knee joint kinematics during functional activity. https://app.cochat.ai/papers/10.1016/j.jbiomech.2010.01.002
- The paper
- Akbarshahi, M., Schache, A. G., Fernandez, J. W., Baker, R., Banks, S., & Pandy, M. G. (2010). Non-invasive assessment of soft-tissue artifact and its effect on knee joint kinematics during functional activity. Journal of Biomechanics. https://doi.org/10.1016/j.jbiomech.2010.01.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.