The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Loading of the knee joint during activities of daily living measured in vivo in five subjects
Abstract
Detailed knowledge about loading of the knee joint is essential for preclinical testing of implants, validation of musculoskeletal models and biomechanical understanding of the knee joint. The contact forces and moments acting on the tibial component were therefore measured in 5 subjects in vivo by an instrumented knee implant during various activities of daily living. Average peak resultant forces, in percent of body weight, were highest during stair descending (346% BW), followed by stair ascending (316% BW), level walking (261% BW), one legged stance (259% BW), knee bending (253% BW), standing up (246% BW), sitting down (225% BW) and two legged stance (107% BW). Peak shear forces were about 10-20 times smaller than the axial force. Resultant forces acted almost vertically on the tibial plateau even during high flexion. Highest moments acted in the frontal plane with a typical peak to peak range -2.91% BWm (adduction moment) to 1.61% BWm (abduction moment) throughout all activities. Peak flexion/extension moments ranged between -0.44% BWm (extension moment) and 3.16% BWm (flexion moment). Peak external/internal torques lay between -1.1% BWm (internal torque) and 0.53% BWm (external torque). The knee joint is highly loaded during daily life. In general, resultant contact forces during dynamic activities were lower than the ones predicted by many mathematical models, but lay in a similar range as measured in vivo by others. Some of the observed load components were much higher than those currently applied when testing knee implants.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This loading condition represented a worst-case outcome for the ACL during walking (Kutzner et al., 2010).”
From The Femoral Tunnel Drilling Angle at 45° Coronal and 45° Sagittal Provided the Lowest Peak Stress and Strain on the Bone Tunnels and Anterior Cruciate Ligament Graft (2021) · cites this paper as Kutzner et al., 2010
Citations
Cites
The mechanics of the knee joint in relation to normal walking
Morrison, J. B. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90050-3 · Cited by 1,062
The prediction of muscular load sharing and joint forces in the lower extremities during walking
Seireg, A. A., & Arvikar, R. J. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90089-5 · Cited by 500
Tibio‐femoral loading during human gait and stair climbing
Taylor, W. R., Heller, M. O. W., Bergmann, G., & Duda, G. N. (2003) · Journal of Orthopaedic Research® · doi:10.1016/j.orthres.2003.09.003 · Cited by 377
Knee and hip kinetics during normal stair climbing
Costigan, P. A., Deluzio, K. J., & WYSS, U. P. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00201-6 · Cited by 325
Function of the knee joint in various activities.
Morrison, J. B. (1969) · PubMed · Cited by 318
Alignment of curves by dynamic time warping
Wang, K., & Gasser, T. (1997) · The Annals of Statistics · doi:10.1214/aos/1069362747 · Cited by 296
Mündermann, A., Dyrby, C. O., DʼLima, D. D., Colwell, C. W., & Andriacchi, T. P. (2008) · Journal of Orthopaedic Research® · doi:10.1002/jor.20655 · Cited by 250
Taylor, S. J. G., Walker, P. S., Perry, J. S., Cannon, S. R., & WOLEDGE, R. C. (1998) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(98)90009-2 · Cited by 246
Tibial Forces Measured In Vivo After Total Knee Arthroplasty
DʼLima, D. D., Patil, S. S., Steklov, N., Slamin, J. E., & Colwell, C. W. (2006) · The Journal of Arthroplasty · doi:10.1016/j.arth.2005.07.011 · Cited by 232
Heinlein, B., Kutzner, I., Graichen, F., Bender, A., Rohlmann, A., Halder, A. M., Beier, A., & Bergmann, G. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.01.011 · Cited by 201
Cited by
Sorted by citations
Grand challenge competition to predict in vivo knee loads
Fregly, B. J., Besier, T. F., Lloyd, D. G., Delp, S. L., Banks, S. A., Pandy, M. G., & DʼLima, D. D. (2011) · Journal of Orthopaedic Research® · doi:10.1002/jor.22023 · Cited by 598
Standardized Loads Acting in Hip Implants
Bergmann, G., Bender, A., Dymke, J., Duda, G. N., & Damm, P. (2016) · PLoS ONE · doi:10.1371/journal.pone.0155612 · Cited by 565
Standardized Loads Acting in Knee Implants
Bergmann, G., Bender, A., Graichen, F., Dymke, J., Rohlmann, A., Trepczynski, A., Heller, M. O. W., & Kutzner, I. (2014) · PLoS ONE · doi:10.1371/journal.pone.0086035 · Cited by 387
Compressive tibiofemoral force during crouch gait
Steele, K. M., DeMers, M. S., Schwartz, M. H., & Delp, S. L. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2011.11.023 · Cited by 381
Osteolysis around total knee arthroplasty: A review of pathogenetic mechanisms
Gallo, J., Goodman, S. B., Konttinen, Y. T., Wimmer, M. A., & Holinka, M. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.05.005 · Cited by 354
Metadata
- Authors
- Kutzner, I., Heinlein, B., Graichen, F., Bender, A., Rohlmann, A., Halder, A., Beier, A., & Bergmann, G.
- Affiliations
- Charité – Universitätsmedizin Berlin (DE)
- Berlin-Brandenburger Centrum für Regenerative Therapien (DE)
- Corresponding author
- Kutzner, I.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2010-08
- Volume
- 43
- Issue
- 11
- Pages
- 2164-2173
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W1972617433
- Cited by
- 798
- References
- 19
- Citations by year
- 2026: 55 · 2025: 48 · 2024: 42 · 2023: 38 · 2022: 66 · 2021: 49 · 2020: 52 · 2019: 70 · 2018: 65 · 2017: 56 · 2016: 49 · 2015: 49 · 2014: 51 · 2013: 50 · 2012: 28
- FWCI
- 36.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Total Knee Arthroplasty Outcomes
- Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Keywords
- knee joint loading, activities of daily living, in vivo measurement, shear force, stair climbing, walking, knee flexion
- MeSH terms
- Activities of Daily Living, Aged, Computer Simulation, Female, Humans, Knee Joint, Male, Middle Aged, Models, Biological, Stress, Mechanical, Weight-Bearing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review