TLEM 2.0 – A comprehensive musculoskeletal geometry dataset for subject-specific modeling of lower extremity
Open accessThe DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Full-Body Musculoskeletal Model for Muscle-Driven Simulation of Human Gait
Rajagopal, A., Dembia, C. L., DeMers, M. S., Delp, D. D., Hicks, J. L., & Delp, S. L. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2586891 · Cited by 1,053
Marra, M. A., Vanheule, V., Fluit, R., Koopman, B. H. F. J. M., Rasmussen, J., Verdonschot, N., & Andersen, M. S. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029258 · Cited by 278
Self-citationWibawa, A. D., Verdonschot, N., Halbertsma, J. P. K., Burgerhof, J. G. M., Diercks, R. L., & Verkerke, G. J. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.09.041 · Cited by 25
Self-citationAltered Muscle Contributions are Required to Support the Stance Limb During Voluntary Toe-Walking
De Pieri, E., Romkes, J., Wyss, C., Brunner, R., & Viehweger, E. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.810560 · Cited by 12
“Themodeling framework developed in this study was based on 3-dimensional optical motion-capture gait data and an accurate 3-dimensional geometrical representation of the lower-limb based on cadaveric data (Carbone et al., 2015; De Pieri et al., 2018).”
Method
Metadata
- Authors
- Carbone, V., Fluit, R., Pellikaan, P., van der Krogt, M. M., Janssen, D., Damsgaard, M., Vigneron, L., Feilkas, T., Koopman, H. F. J. M., & Verdonschot, N.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2015-03
- Volume
- 48
- Issue
- 5
- Pages
- 734-741
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2161973464
- Cited by
- 202
- References
- 0
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.