Analysis of Forearm Rotational Motion Using Biplane Fluoroscopic Intensity-Based 2D-3D Matching
Open accessAbstract
Measuring three-dimensional (3D) forearm rotational motion is difficult. We aimed to develop and validate a new method for analyzing 3D forearm rotational motion. We proposed biplane fluoroscopic intensity-based 2D-3D matching, which employs automatic registration processing using the evolutionary optimization strategy. Biplane fluoroscopy was conducted for forearm rotation at 12.5 frames per second along with computed tomography (CT) at one static position. An arm phantom was embedded with eight stainless steel spheres (diameter, 1.5 mm), and forearm rotational motion measurements using the proposed method were compared with those using radiostereometric analysis, which is considered the ground truth. As for the time resolution analysis, we measured radiohumeral joint motion in a patient with posterolateral rotatory instability and compared the 2D-3D matching method with the simulated multiple CT method, which uses CTs at multiple positions and interpolates between the positions. Rotation errors of the radius and ulna between these two methods were 0.31 ± 0.35° and 0.32 ± 0.33°, respectively, translation errors were 0.43 ± 0.35 mm and 0.29 ± 0.25 mm, respectively. Although the 2D-3D method could detect joint dislocation, the multiple CT method could not detect quick motion during joint dislocation. The proposed method enabled high temporal- and spatial-resolution motion analyses with low radiation exposure. Moreover, it enabled the detection of a sudden motion, such as joint…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Traditional intensity-based registration methods are routinely employed to solve compound, multiple object registration problems across broad applications.
“Despite the small number of learning-based multiple object registration strategies, traditional intensity-based registration methods are now routinely employed to solve compound, multiple object, registration problems across broad applications, such as: kinematic measurements of bone (Chen et al., 2012; Otake et al., 2016; Abe et al., 2019), rib motion and respiratory analysis (Hiasa et al., 2019)”
From The Impact of Machine Learning on 2D/3D Registration for Image-Guided Interventions: A Systematic Review and Perspective (2021) · cites this paper as Abe et al., 2019
Cites
Otake, Y., Wang, A. S., Webster Stayman, J., Uneri, A., Kleinszig, G., Vogt, S., Khanna, A. J., Gokaslan, Z. L., & Siewerdsen, J. H. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/23/8535 · Cited by 85 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Unberath, M., Gao, C., Hu, Y., Judish, M., Taylor, R. H., Armand, M., & Grupp, R. (2021) · Frontiers in Robotics and AI · doi:10.3389/frobt.2021.716007 · Cited by 102 · see citing works
“…employed to solve compound, multiple object, registration problems across broad applications, such as: kinematic measurements of bone [99, 100, 101], rib motion and respiratory analysis [102], intra-operative assessment of adjusted bone fragments [20, 18, 103], confirmation of screw implant…”
Background
- Authors
- Abe, S., Otake, Y., Tennma, Y., Hiasa, Y., Oka, K., Tanaka, H., Shigi, A., Miyamura, S., Sato, Y., & Murase, T.
- Affiliations
- Toyonaka Municipal Hospital (JP)
- Nara Institute of Science and Technology (JP)
- The University of Osaka (JP)
- Corresponding author
- Murase, Tsuyoshi
- ORCID
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2019-05
- Volume
- 89
- Pages
- 128-133
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2937697758
- Cited by
- 8
- References
- 1
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 1 · 2023: 1 · 2021: 3
- FWCI
- 0.34
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of Biomechanics (acceptedVersion)
- PubMed (publishedVersion)
- Funders
- MEXT
- JSPS (KAKENHI 26108004, KAKENHI 15K10442)
- JST (PRESTO 20407)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Health Sciences › Medicine › Rehabilitation › Elbow and Forearm Trauma Treatment
- Health Sciences › Medicine › Surgery › Shoulder Injury and Treatment
- Keywords
- biplane fluoroscopy, evolutionary optimization, radiostereometric analysis, posterolateral rotatory instability, stainless steel spheres, temporal resolution
- MeSH terms
- Fluoroscopy, Forearm, Humans, Movement, Radius, Rotation, Ulna, Phantoms, Imaging, Imaging, Three-Dimensional
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review