Cited by 8Medical Image Segmentation TechniquesElbow and Forearm Trauma TreatmentShoulder Injury and Treatment

Analysis of Forearm Rotational Motion Using Biplane Fluoroscopic Intensity-Based 2D-3D Matching

Open access
Abe, Shingo, Otake, Yoshito, Tennma, Yusuke, Hiasa, Yuta, Oka, Kunihiro, Tanaka, Hiroyuki, Shigi, Atsuo, Miyamura, Satoshi +2 more·2019·Journal of Biomechanics

Abstract

Measuring three-dimensional (3D) forearm rotational motion is difficult. We aimed to develop and validate a new method for analyzing 3D forearm rotational motion. We proposed biplane fluoroscopic intensity-based 2D-3D matching, which employs automatic registration processing using the evolutionary optimization strategy. Biplane fluoroscopy was conducted for forearm rotation at 12.5 frames per second along with computed tomography (CT) at one static position. An arm phantom was embedded with eight stainless steel spheres (diameter, 1.5 mm), and forearm rotational motion measurements using the proposed method were compared with those using radiostereometric analysis, which is considered the ground truth. As for the time resolution analysis, we measured radiohumeral joint motion in a patient with posterolateral rotatory instability and compared the 2D-3D matching method with the simulated multiple CT method, which uses CTs at multiple positions and interpolates between the positions. Rotation errors of the radius and ulna between these two methods were 0.31 ± 0.35° and 0.32 ± 0.33°, respectively, translation errors were 0.43 ± 0.35 mm and 0.29 ± 0.25 mm, respectively. Although the 2D-3D method could detect joint dislocation, the multiple CT method could not detect quick motion during joint dislocation. The proposed method enabled high temporal- and spatial-resolution motion analyses with low radiation exposure. Moreover, it enabled the detection of a sudden motion, such as joint…

Integrity signals

Registry

Crossref · 10.1016/j.jbiomech.2019.04.017

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Traditional intensity-based registration methods are routinely employed to solve compound, multiple object registration problems across broad applications.

    “Despite the small number of learning-based multiple object registration strategies, traditional intensity-based registration methods are now routinely employed to solve compound, multiple object, registration problems across broad applications, such as: kinematic measurements of bone (Chen et al., 2012; Otake et al., 2016; Abe et al., 2019), rib motion and respiratory analysis (Hiasa et al., 2019)”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Abe, S., Otake, Y., Tennma, Y., Hiasa, Y., Oka, K., Tanaka, H., Shigi, A., Miyamura, S., Sato, Y., & Murase, T.
Affiliations
  • Toyonaka Municipal Hospital (JP)
  • Nara Institute of Science and Technology (JP)
  • The University of Osaka (JP)
Corresponding author
Murase, Tsuyoshi
Venue
Journal of Biomechanics
Publisher
Elsevier BV
Published
2019-05
Volume
89
Pages
128-133
ISSN
0021-9290 (ISSN-L)
OpenAlex
W2937697758
Cited by
8
References
1
Citations by year
2026: 1 · 2025: 2 · 2024: 1 · 2023: 1 · 2021: 3
FWCI
0.34
Type
journal article
Language
en
Open access
Locations
  • Journal of Biomechanics (acceptedVersion)
  • PubMed (publishedVersion)
Funders
  • MEXT
  • JSPS (KAKENHI 26108004, KAKENHI 15K10442)
  • JST (PRESTO 20407)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Health Sciences › Medicine › Rehabilitation › Elbow and Forearm Trauma Treatment
  • Health Sciences › Medicine › Surgery › Shoulder Injury and Treatment
Keywords
biplane fluoroscopy, evolutionary optimization, radiostereometric analysis, posterolateral rotatory instability, stainless steel spheres, temporal resolution
MeSH terms
Fluoroscopy, Forearm, Humans, Movement, Radius, Rotation, Ulna, Phantoms, Imaging, Imaging, Three-Dimensional

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review