Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 196

The DOI matches its Crossref record.

A comparison of currently available optoelectronic motion capture systems

Topley, Matt, Richards, James G.·2020·Journal of Biomechanics

Abstract

The measurement of human motion relies heavily on the ability of the optoelectronic motion capture systems to accurately measure retroreflective marker positions. Marker position accuracy is largely dependent on the optical characteristics of the camera system and algorithms implemented in the tracking software. In 1999, Richards critically reviewed multiple camera systems and each of their ability to generate the same marker coordinate positions under different field tests. Field tests were designed utilizing what became to be known as the Standard Assessment of Motion System Accuracy (SAMSA) device. The SAMSA test results indicated that some systems outperformed others and accuracy varied depending on the test. In the subsequent 20 years, motion capture technology has significantly improved. Therefore, we aimed to replicate the tests from 1999 using current, higher-resolution motion capture systems and current calibration techniques. Reference marker distances were established utilizing a FaroArm 3D digitizer (FARO technologies). The modern cameras field test performance showed nearly a three-fold improvement in agreement with the reference measure compared to their 1999 predecessors. No systems' absolute marker distance measured greater than 0.5 mm from the FaroArm measurement and no systems' maximum error exceeded 1.0 mm. Given the consistency in accuracy reported by all the systems included in the current assessment, it's reasonable to assume that the current systems would eliminate errors associated with system hardware/software as an obstacle to sharing data between laboratories.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jbiomech.2020.109820

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 196

Metadata

Authors
Topley, M., & Richards, J. G.
Venue
Journal of Biomechanics
Publisher
Elsevier BV
Published
2020-06
Volume
106
Pages
109820
ISSN
0021-9290 (ISSN-L)
OpenAlex
W3019333129
Cited by
196
References
0
FWCI
12.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A comparison of currently available optoelectronic motion capture systems. https://app.cochat.ai/papers/10.1016/j.jbiomech.2020.109820
The paper
Topley, M., & Richards, J. G. (2020). A comparison of currently available optoelectronic motion capture systems. Journal of Biomechanics. https://doi.org/10.1016/j.jbiomech.2020.109820

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.