A comparison of currently available optoelectronic motion capture systems
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The measurement of human motion relies heavily on the ability of the optoelectronic motion capture systems to accurately measure retroreflective marker positions. Marker position accuracy is largely dependent on the optical characteristics of the camera system and algorithms implemented in the tracking software. In 1999, Richards critically reviewed multiple camera systems and each of their ability to generate the same marker coordinate positions under different field tests. Field tests were designed utilizing what became to be known as the Standard Assessment of Motion System Accuracy (SAMSA) device. The SAMSA test results indicated that some systems outperformed others and accuracy varied depending on the test. In the subsequent 20 years, motion capture technology has significantly improved. Therefore, we aimed to replicate the tests from 1999 using current, higher-resolution motion capture systems and current calibration techniques. Reference marker distances were established utilizing a FaroArm 3D digitizer (FARO technologies). The modern cameras field test performance showed nearly a three-fold improvement in agreement with the reference measure compared to their 1999 predecessors. No systems' absolute marker distance measured greater than 0.5 mm from the FaroArm measurement and no systems' maximum error exceeded 1.0 mm. Given the consistency in accuracy reported by all the systems included in the current assessment, it's reasonable to assume that the current systems would eliminate errors associated with system hardware/software as an obstacle to sharing data between laboratories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accuracy of human motion capture systems for sport applications; state‐of‐the‐art review
van der Kruk, E., & Reijne, M. M. (2018) · European Journal of Sport Science · doi:10.1080/17461391.2018.1463397 · Cited by 522
The measurement of human motion: A comparison of commercially available systems
Richards, J. G. (1999) · Human Movement Science · doi:10.1016/s0167-9457(99)00023-8 · Cited by 434
Self-citationWindolf, M., Götzen, N., & Morlock, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.06.024 · Cited by 415
Optimal camera placement for accurate reconstruction
Olague, G., & Mohr, R. (2002) · Pattern Recognition · doi:10.1016/s0031-3203(01)00076-0 · Cited by 178
Cited by
Wade, L., Needham, L., McGuigan, P., & Bilzon, J. (2022) · PeerJ · doi:10.7717/peerj.12995 · Cited by 384
Werling, K., Bianco, N. A., Raitor, M., Stingel, J., Hicks, J. L., Collins, S. H., Delp, S. L., & Liu, C. K. (2023) · PLOS ONE · doi:10.1371/journal.pone.0295152 · Cited by 65
“13 Laboratory-based motion capture is the current benchmark data acquisition 14 technique to quantify human biomechanics [21, 22], but current state-of-the-art software 15 for reconstructing the motion and kinetics of a human musculoskeletal model from 16 optical marker trajectories and ground reaction forces requires…”
Metadata
- Authors
- Topley, M., & Richards, J. G.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2020-06
- Volume
- 106
- Pages
- 109820
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W3019333129
- Cited by
- 196
- References
- 4
- FWCI
- 12.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.