Electrochemically active surface area controls HER activity for FexNi100−x films in alkaline electrolyte
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The synthesis and electrocatalytic activity of FexNi100−x electrochemically deposited films were investigated. Films were evaluated for the hydrogen evolution reaction (HER) in alkaline media with respect to composition and electrochemically active surface area (ECSA). Results demonstrate that films of higher or equal Fe content had an ECSA tenfold greater than films with higher Ni. When normalized by geometric surface area, Fe50Ni50 films required the lowest overpotential of −390 mV to reach a current density of −10 mA cm−2. However, when normalized by the ECSA, intrinsic HER activity increases as Ni content increases. Tafel slope, ECSA, microscopy, and impedance spectroscopy analyses allow a decoupled analysis of surface area versus activity effects on overall measured HER activity. These analyses collectively demonstrate that the increase in electrocatalytic activity is attributed to the increase in ECSA and not to an enhancement in the intrinsic activity by Fe and Ni component interactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biesinger, M. C., Payne, B. P., Grosvenor, A. P., Lau, L. W. M., Gerson, A. R., & Smart, R. S. C. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2010.10.051 · Cited by 11,640
Benchmarking Heterogeneous Electrocatalysts for the Oxygen Evolution Reaction
McCrory, C. C. L., Jung, S., Peters, J. C., & Jaramillo, T. F. (2013) · Journal of the American Chemical Society · doi:10.1021/ja407115p · Cited by 7,026
McCrory, C. C. L., Jung, S., Ferrer, I. M., Chatman, S. M., Peters, J. C., & Jaramillo, T. F. (2015) · Journal of the American Chemical Society · doi:10.1021/ja510442p · Cited by 4,145
Recent progress in alkaline water electrolysis for hydrogen production and applications
Zeng, K., & Zhang, D. (2010) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2009.11.002 · Cited by 3,611
Shinagawa, T., Garcia-Esparza, A. T., & Takanabe, K. (2015) · Scientific Reports · doi:10.1038/srep13801 · Cited by 3,287
Buttler, A., & Spliethoff, H. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.09.003 · Cited by 2,510
New interpretations of XPS spectra of nickel metal and oxides
Grosvenor, A. P., Biesinger, M. C., Smart, R. S. C., & McIntyre, N. S. (2006) · Surface Science · doi:10.1016/j.susc.2006.01.041 · Cited by 2,434
Powering the planet with solar fuel
Gray, H. B. (2009) · Nature Chemistry · doi:10.1038/nchem.141 · Cited by 1,731
Crabtree, G. W., Dresselhaus, M. S., & Buchanan, M. V. (2004) · Physics Today · doi:10.1063/1.1878333 · Cited by 1,610
Cited by
Muzammil, A., Haider, R., Wei, W., Wan, Y., Ishaq, M., Zahid, M., Yaseen, W., & Yuan, X. (2023) · Materials Horizons · doi:10.1039/d3mh00335c · Cited by 73
Metadata
- Authors
- Perez Bakovic, S. I., Acharya, P., Watkins, M., Thornton, H., Hou, S., & Greenlee, L. F.
- Venue
- Journal of Catalysis
- Publisher
- Elsevier BV
- Published
- 2021-02
- Volume
- 394
- Pages
- 104-112
- ISSN
- 0021-9517 (ISSN-L)
- OpenAlex
- W3118420335
- Cited by
- 170
- References
- 9
- FWCI
- 3.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.