State-of-the-art in CT hardware and scan modes for cardiovascular CT
Open accessThe DOI matches its Crossref record.
Abstract
Multidetector row computed tomography (CT) allows noninvasive anatomic and functional imaging of the heart, great vessels, and the coronary arteries. In recent years, there have been several advances in CT hardware, which have expanded the clinical utility of CT for cardiovascular imaging; such advances are ongoing. This review article from the Society of Cardiovascular Computed Tomography (SCCT) Basic and Emerging Sciences and Technology (BEST) Working Group summarizes the technical aspects of current state-of-the-art CT hardware and describes the scan modes this hardware supports for cardiovascular CT imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
AI in Medical Imaging Informatics: Current Challenges and Future Directions
Panayides, A. S., Amini, A., Filipovic, N. D., Sharma, A., Tsaftaris, S. A., Young, A., Foran, D., Do, N., Golemati, S., Kurc, T., et al. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2991043 · Cited by 713
“Improved solid-state detectors, common in modern CT scanners, have improved spatial resolutions to 0.25 mm [26], while multiple detector rows enable larger spatial coverage with slice thicknesses down to 0.625 mm. Spectral computed tomography (SCT) utilizes multiple X-ray energy bands that are used…”
InfluentialHan, B. K., Rigsby, C. K., Hlavacek, A., Leipsic, J., Nicol, E. D., Siegel, M. J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.004 · Cited by 211
Computational Medicine: Translating Models to Clinical Care
Winslow, R. L., Trayanova, N., Geman, D., & Miller, M. I. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3003528 · Cited by 202
“More widespread use of state-of-the-art CT systems with large numbers of detectors and better spatiotemporal resolution will help resolve this problem ( 85 ).”
BackgroundHan, B. K., Rigsby, C. K., Leipsic, J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., Raman, S. V., Crean, A. M., Nicol, E. D., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.007 · Cited by 158
Metadata
- Authors
- Halliburton, S., Arbab-Zadeh, A., Dey, D., Einstein, A. J., Gentry, R., George, R. T., Gerber, T., Mahesh, M., & Weigold, W. G.
- Venue
- Journal of Cardiovascular Computed Tomography
- Publisher
- Elsevier BV
- Published
- 2012-05
- Volume
- 6
- Issue
- 3
- Pages
- 154-163
- ISSN
- 1876-861X (ISSN-L)
- 1934-5925
- OpenAlex
- W2034859255
- Cited by
- 82
- References
- 0
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: State-of-the-art in CT hardware and scan modes for cardiovascular CT. https://app.cochat.ai/papers/10.1016/j.jcct.2012.04.005
- The paper
- Halliburton, S., Arbab-Zadeh, A., Dey, D., Einstein, A. J., Gentry, R., George, R. T., Gerber, T., Mahesh, M., & Weigold, W. G. (2012). State-of-the-art in CT hardware and scan modes for cardiovascular CT. Journal of Cardiovascular Computed Tomography. https://doi.org/10.1016/j.jcct.2012.04.005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.