CoChat

CT ​Evaluation ​by ​Artificial ​Intelligence ​for ​Atherosclerosis, Stenosis and Vascular ​Morphology ​(CLARIFY): ​A ​Multi-center, international study

Open access
Choi, Andrew D., Marques, Hugo, Kumar, Vishak, Griffin, William F., Rahban, Habib, Karlsberg, Ronald P., Zeman, Robert K., Katz, Richard J., Earls, James P. · 2021 · Journal of Cardiovascular Computed Tomography
Cited by 231

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Atherosclerosis evaluation by coronary computed tomography angiography (CCTA) is promising for coronary artery disease (CAD) risk stratification, but time consuming and requires high expertise. Artificial Intelligence (AI) applied to CCTA for comprehensive CAD assessment may overcome these limitations. We hypothesized AI aided analysis allows for rapid, accurate evaluation of vessel morphology and stenosis. METHODS: This was a multi-site study of 232 patients undergoing CCTA. Studies were analyzed by FDA-cleared software service that performs AI-driven coronary artery segmentation and labeling, lumen and vessel wall determination, plaque quantification and characterization with comparison to ground truth of consensus by three L3 readers. CCTAs were analyzed for: % maximal diameter stenosis, plaque volume and composition, presence of high-risk plaque and Coronary Artery Disease Reporting & Data System (CAD-RADS) category. RESULTS: AI performance was excellent for accuracy, sensitivity, specificity, positive predictive value and negative predictive value as follows: >70% stenosis: 99.7%, 90.9%, 99.8%, 93.3%, 99.9%, respectively; >50% stenosis: 94.8%, 80.0%, 97.0, 80.0%, 97.0%, respectively. Bland-Altman plots depict agreement between expert reader and AI determined maximal diameter stenosis for per-vessel (mean difference -0.8%; 95% CI 13.8% to -15.3%) and per-patient (mean difference -2.3%; 95% CI 15.8% to -20.4%). L3 and AI agreed within one CAD-RADS category in 228/232 (98.3%) exams per-patient and 923/924 (99.9%) vessels on a per-vessel basis. There was a wide range of atherosclerosis in the coronary artery territories assessed by AI when stratified by CAD-RADS distribution. CONCLUSIONS: AI-aided approach to CCTA interpretation determines coronary stenosis and CAD-RADS category in close agreement with consensus of L3 expert readers. There was a wide range of atherosclerosis identified through AI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcct.2021.05.004

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 41 references

Cited by

See all 231

Metadata

Authors
Choi, A. D., Marques, H., Kumar, V., Griffin, W. F., Rahban, H., Karlsberg, R. P., Zeman, R. K., Katz, R. J., & Earls, J. P.
Venue
Journal of Cardiovascular Computed Tomography
Publisher
Elsevier BV
Published
2021-11
Volume
15
Issue
6
Pages
470-476
ISSN
  • 1876-861X (ISSN-L)
  • 1934-5925
OpenAlex
W3165991538
Cited by
231
References
41
FWCI
15.06
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: CT ​Evaluation ​by ​Artificial ​Intelligence ​for ​Atherosclerosis, Stenosis and Vascular ​Morphology ​(CLARIFY): ​A ​Multi-center, international study. https://app.cochat.ai/papers/10.1016/j.jcct.2021.05.004
The paper
Choi, A. D., Marques, H., Kumar, V., Griffin, W. F., Rahban, H., Karlsberg, R. P., Zeman, R. K., Katz, R. J., & Earls, J. P. (2021). CT ​Evaluation ​by ​Artificial ​Intelligence ​for ​Atherosclerosis, Stenosis and Vascular ​Morphology ​(CLARIFY): ​A ​Multi-center, international study. Journal of Cardiovascular Computed Tomography. https://doi.org/10.1016/j.jcct.2021.05.004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.