High performance liquid chromatographic determination of azithromycin in serum using fluorescence detection and its application in human pharmacokinetic studies
Abstract
A fast and sensitive high-performance liquid chromatographic method for determination of azithromycin in human serum using fluorescence detection was developed. The drug and an internal standard (clarithromycin) were extracted from serum using n-hexan and subjected to pre-column derivatization with 9-fluorenylmethyl chloroformate as labeling agent. Analysis was performed on a phenyl packing material column with sodium phosphate buffer containing 2 ml/l triethylamine (pH 5.9) and methanol (29:71, v/v) as the mobile phase. The standard curve was linear over the range of 10-500 ng/ml of azithromycin in human serum. The means between-days precision were from 13.3% (for 10 ng/ml) to 2% (500 ng/ml) and the within-day precision from 11.9 to 1.7% determined on spiked samples. The accuracy of the method was 100.7-107.2% (between days) and 100.3-107.8% (within day). The limit of quantification was 10 ng/ml. This method was applied in a bioequivalence study of four different azithromycin preparations in 12 healthy volunteers.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Anhydrides, acetyl chlorides and benzoyl chlorides have been widely employed for derivatizing molecules containing alcohol and phenol groups.
“Anhydrides, acetyl chlorides and benzoyl chlorides have been widely employed for derivatizing molecules containing alcohol and phenol groups.108,109”
From Connecting metabolome and phenotype: recent advances in functional metabolomics tools for the identification of bioactive natural products (2024) · cites this paper as [109]
The citation lists haven’t been fetched yet
References 8 · Cited by 62
- Authors
- BAHRAMI, G., MIRZAEEI, S., & KIANI, A.
- Affiliations
- Kermanshah University of Medical Sciences (IR)
- Corresponding author
- BAHRAMI, G
- ORCID
- Venue
- Journal of Chromatography B
- Publisher
- Elsevier BV
- Published
- 2005-06-25
- Volume
- 820
- Issue
- 2
- Pages
- 277-281
- ISSN
- 1570-0232 (ISSN-L)
- OpenAlex
- W2052478053
- Cited by
- 62
- References
- 8
- Citations by year
- 2025: 1 · 2024: 5 · 2022: 3 · 2021: 2 · 2020: 2 · 2019: 3 · 2018: 2 · 2016: 4 · 2015: 1 · 2014: 5 · 2013: 6 · 2012: 7
- FWCI
- 4.40
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Chromatography B (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Health Sciences › Medicine › Pharmacology (medical) › Antibiotics Pharmacokinetics and Efficacy
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Keywords
- azithromycin, serum drug quantification, pharmacokinetics, fluorescence detection, bioequivalence, macrolide antibiotics, hexane extraction
- MeSH terms
- Anti-Bacterial Agents, Calibration, Chromatography, High Pressure Liquid, Humans, Sensitivity and Specificity, Spectrometry, Fluorescence, Therapeutic Equivalency, Reproducibility of Results, Azithromycin
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review