Quantification of 22 phthalate metabolites in human urine☆
Abstract
Phthalates are ubiquitous industrial chemicals with high potential for human exposure. Validated analytical methods to measure trace concentrations of phthalate metabolites in humans are essential for assessing exposure to phthalates. Previously, we developed a sensitive and accurate automated analytical method for measuring up to 16 phthalate metabolites in human urine by using on-line solid phase extraction coupled with isotope dilution-high performance liquid chromatography (HPLC)-electrospray ionization-tandem mass spectrometry. To include the measurement of seven additional analytes, including oxidative metabolites of diisononyl and diisodecyl phthalates, two chemicals used extensively in numerous consumer products, we used a novel nontraditional HPLC solvent gradient program. With this approach, we achieved adequate resolution and sensitivity for all 22 analytes with limits of detection in the low ng/mL range, without increasing the analytical run time. The method also has high accuracy with automatic recovery correction, high precision, and excellent sample throughput with minimal matrix effects. Although it is possible to measure these 22 phthalate metabolites with adequate precision and accuracy at sub-parts-per-billion levels, additional information, including toxicokinetic data, is needed to demonstrate the usefulness of these phthalate metabolites for exposure assessment purposes.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The oxidative metabolites MEOHP, MEHHP, MECPP, and MCMHP are the major metabolites of DEHP and are appropriate biomarkers of exposure to DEHP.
“The oxidative metabolites, MEOHP, MEHHP, MECPP, and MCMHP, however, are the major metabolites of DEHP and are appropriate biomarkers of exposure to this compound [21].”
From A Review of Biomonitoring of Phthalate Exposures (2019) · cites this paper as [21]
In general, the concentrations of the sum of 22 phthalate metabolites measured in human urine were on the order of several to hundreds of μg/L.
“In general, the concentrations of the sum of 22 phthalate metabolites measured in human urine were on the order of several to hundreds of parts-per-billion (µg/L) [21].”
From A Review of Biomonitoring of Phthalate Exposures (2019) · cites this paper as [21]
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 21 · Cited by 445
- Authors
- SILVA, M., SAMANDAR, E., PREAUJR, J., REIDY, J., NEEDHAM, L., & CALAFAT, A.
- Affiliations
- Centers for Disease Control and Prevention (US)
- Corresponding author
- SILVA, M
- ORCID
- CALAFAT, A
- Venue
- Journal of Chromatography B
- Publisher
- Elsevier BV
- Published
- 2007-12-01
- Volume
- 860
- Issue
- 1
- Pages
- 106-112
- ISSN
- 1570-0232 (ISSN-L)
- OpenAlex
- W2019913219
- Cited by
- 445
- References
- 21
- Citations by year
- 2026: 10 · 2025: 20 · 2024: 34 · 2023: 29 · 2022: 42 · 2021: 28 · 2020: 32 · 2019: 33 · 2018: 46 · 2017: 18 · 2016: 23 · 2015: 36 · 2014: 19 · 2013: 19 · 2012: 16
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Chromatography B (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Effects and risks of endocrine disrupting chemicals
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
- Keywords
- phthalate metabolites, human urine, on-line solid-phase extraction, isotope dilution, HPLC-ESI-MS/MS, diisononyl phthalate, diisodecyl phthalate, oxidative metabolites, toxicokinetics
- MeSH terms
- Chromatography, High Pressure Liquid, Environmental Exposure, Humans, Phthalic Acids, Reproducibility of Results, Biomarkers, Spectrometry, Mass, Electrospray Ionization, Tandem Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review