CoChat

A liquid chromatography–tandem mass spectrometric method for quantification of curcuminoids in cell medium and mouse plasma

Open access
Vijaya Saradhi, U.V.R., Ling, Yonghua, Wang, Jiang, Chiu, Ming, Schwartz, Eric B., Fuchs, James R., Chan, Kenneth K., Liu, Zhongfa · 2010 · Journal of Chromatography B
Cited by 58

The DOI matches its Crossref record.

Abstract

Curcumin and tetrahydrocurcumin (THC) have been found as potent DNMT1 inhibitors, but they suffer from low oral bioavailability and rapid metabolism in vivo. To circumvent these problems, two curcumin analogs: 1,7-bis(3,4-dimethoxyphenyl)-4,4-dimethyl-1,6-heptadiene-3,5-dione (TMC) and 1,7-bis(3,4-dimethoxyphenyl)-4-cyclohexyl-1,6-heptadiene-3,5-dione (DMCHC) have been synthesized to enhance their stability by blocking the two metabolic sites, the phenolic and C4 methylene moieties. Both compounds have shown inhibitory activity on M. SssI similar to that of curcumin and THC (Poster, M1114, AAPS, 2009). Preclinical pharmacokinetics has yet to be performed. In this paper, a simple liquid chromatography–tandem mass spectrometric method was developed for the determination of these four curcuminoids in cell medium and mouse plasma. The method showed linearity from 1 to 1000 ng/mL with the lower limit of quantification of 1 ng/mL in cell medium, and 5 ng/mL in mouse plasma for all test curcuminoids. The within-day coefficients of variation were found to be below 15% and the accuracy was in the range of 85% to 115%. This method was subsequently used to evaluate their stability in these matrices and a pilot pharmacokinetics of curcumin, DMCHC and TMC in mice after an intraperitoneal (I.P.) cassette dosing of 10 mg/kg each. Curcuminoids degraded in two phases with terminal half lives of 186, 813, 724, and 2000 min for curcumin, THC, TMC, and DMCHC, respectively, in cell culture medium. In plasma, their respective half lives were 111, 232, 1202 and 3000 min. These data demonstrated that their stability is in the order curcumin<THC<TMC< DMCHC in both matrices. Following an i.p. cassette dose, Both TMC and DMCHC showed the prolonged elimination half life (1.0, 1.0 h respectively vs 0.4 h for curcumin) and an increased drug exposure as described by the area under the curve (0.64, 0.98 μM*h respectively vs 0.4 μM*h for curcumin).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jchromb.2010.08.039

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Vijaya Saradhi, U. V. R., Ling, Y., Wang, J., Chiu, M., Schwartz, E. B., Fuchs, J. R., Chan, K. K., & Liu, Z.
Venue
Journal of Chromatography B
Publisher
Elsevier BV
Published
2010-11
Volume
878
Issue
30
Pages
3045-3051
ISSN
1570-0232 (ISSN-L)
OpenAlex
W2031872437
Cited by
58
References
0
FWCI
0.80
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.