Deciphering the influence of column chemistry and mass spectrometry settings for the analyses of geometrical isomers of L-chicoric acid
Abstract
Resolving the chemo-diversity of plant extract samples is an essential step for in-depth analyses of natural products which often exhibit promising biological activities. One of the challenges in this endeavor has been the confident differentiation of geometrical isomers. In this study, we investigated these aspects in chromatography (column chemistry and mobile phase composition) and mass spectrometry settings with regards to better differentiation of geometrical isomers. A standard of a hydroxycinnamic acid (HCA) derivative, L-chicoric acid (L-CA) - a di-acylated caffeoyltartaric acid ester found in a number of plant families - was used. Geometrical isomers of L-CA were formed by exposing the compound to ultraviolet (UV) radiation, to mimic the natural environment. The high performance liquid chromatography photo-diode array (HPLC-PDA) and ultra-high performance liquid chromatography mass spectrometry (UHPLC-MS) platforms were used to analyze the trans and cis geometrical isomers of L-CA. The HPLC-PDA results confirmed the generation of two cis geometrical isomers following UV exposure of the authentic trans-L-CA standard. Furthermore, the HPLC-PDA analyses demonstrated that the changes in both column chemistry (reverse-phase: C 18, biphenyl, phenyl-hexyl and pentafluorophenyl propyl) and mobile phase composition (aqueous acetonitrile and aqueous methanol) affect the chromatographic elution profiles of the L-CA isomers. The MS results, on the other hand, revealed undisputed fragmentation differences between the geometrical isomers of L-CA. Thus, this study demonstrates that the identification of the L-CA isomers can be achieved more efficiently and confidently with good chromatography coupled to well-optimized mass spectrometry conditions, a requirement which has been proven impossible with other types of HCA derivatives. Moreover, differences in the binding modes of L-CA geometrical isomers to the HIV type 1 integrase enzyme were observed, suggesting a synergistic anti-HIV-1 activity of these isomers.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 30 · Cited by 12
- Authors
- Masike, K., Tugizimana, F., Ndlovu, N., Smit, E., du Preez, L., Dubery, I., & Madala, E.
- Affiliations
- University of Johannesburg (ZA)
- Venue
- Journal of Chromatography B
- Publisher
- Elsevier BV
- Published
- 2017-05
- Volume
- 1052
- Pages
- 73-81
- ISSN
- 1570-0232 (ISSN-L)
- OpenAlex
- W2603646476
- Cited by
- 12
- References
- 30
- Citations by year
- 2026: 2 · 2024: 2 · 2023: 1 · 2022: 1 · 2021: 2 · 2020: 1 · 2018: 3
- FWCI
- 0.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Chromatography B (publishedVersion)
- PubMed (publishedVersion)
- Funders
- University of Johannesburg
- National Research Foundation of South Africa
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
- Physical Sciences › Chemistry › Analytical Chemistry › Chromatography in Natural Products
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Keywords
- cis-trans isomers, cis-trans isomerization, UV-induced isomerization, hydroxycinnamic acid derivatives, mobile phase composition, mass spectral fragmentation, HPLC-DAD, UHPLC-MS, anti-HIV-1 activity, natural products
- MeSH terms
- Caffeic Acids, Chromatography, High Pressure Liquid, Humans, Isomerism, Mass Spectrometry, Succinates, HIV-1, HIV Infections, HIV Integrase, HIV Integrase Inhibitors, Molecular Docking Simulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review