Cited by 46Per- and polyfluoroalkyl substances researchAnalytical chemistry methods developmentPesticide Residue Analysis and Safety

Simultaneous determination of 21 trace perfluoroalkyl substances in fish by isotope dilution ultrahigh performance liquid chromatography tandem mass spectrometry

Gao, Yan, Li, Xiaomin, Li, Xiuqin, Zhang, Qinghe, Li, Hongmei·2018·Journal of Chromatography B

Abstract

Perfluoroalkyl substances (PFASs) have been identified as emerging environmental contaminants. In this study, an efficient and accurate ultrahigh performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method was developed for simultaneous determination of 21 PFASs in fish. Acetonitrile was used for sample extraction. Solid phase extraction (SPE) by WAX cartridges and then freezing at -30 °C were adopted as cleanup strategies. Strict measurements were performed to control background contamination during the whole procedure. Matrix effects were evaluated by external standard and isotope dilution mass spectrometry (IDMS) methods. IDMS can compensate the matrix effects to a large extent. The method detection limits (MDLs) ranged from 2 pg/g to 10 pg/g except for PFBA (120 pg/g). The method quantitation limits (MQLs) ranged from 5 pg/g to 30 pg/g except for PFBA (300 pg/g). The matrix spiked recoveries of three spiked levels were in the range of 79.6%-109%. The intra-day relative standard deviation (RSD) and inter-day RSD were from 0.94% to 13.9% and 0.36% to 11.2% respectively. Two fish tissue reference materials were analyzed by the developed method. The results of reference materials were within the uncertainty of the given value. The quantitative results of IDMS and standard addition (SA) - IDMS were comparable. The developed UHPLC-MS/MS method was applied for PFASs detection in 20 marine fish samples. 9 PFASs were detected in the samples with the ∑9 PFASs concentration range of 0.04 to 2.14 ng/g wet weight (ww).

Integrity signals

Registry

Crossref · 10.1016/j.jchromb.2018.03.008

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 47 · Cited by 46

Authors
Gao, Y., Li, X., Li, X., Zhang, Q., & Li, H.
Affiliations
National Institute of Metrology (CN)
Corresponding author
Zhang, Qinghe
Venue
Journal of Chromatography B
Publisher
Elsevier BV
Published
2018-05
Volume
1084
Pages
45-52
ISSN
1570-0232 (ISSN-L)
OpenAlex
W2791791343
Cited by
46
References
47
Citations by year
2026: 1 · 2025: 9 · 2024: 10 · 2023: 5 · 2022: 7 · 2021: 5 · 2020: 5 · 2019: 2 · 2018: 2
FWCI
1.83
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Chromatography B (publishedVersion)
  • PubMed (publishedVersion)
Funders
Research and Application of the Common Technology of National Quality Infrastructure (2016YFF0201106)
Topics
  • Physical Sciences › Environmental Science › Environmental Chemistry › Per- and polyfluoroalkyl substances research
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
Keywords
perfluorinated compounds, isotope dilution mass spectrometry, matrix effects, marine fish contamination, solid-phase extraction cleanup, simultaneous determination, emerging contaminants, perfluorobutanoic acid
MeSH terms
Animals, Chromatography, High Pressure Liquid, Environmental Monitoring, Fishes, Fluorocarbons, Water Pollutants, Chemical, Reproducibility of Results, Linear Models, Seafood, Tandem Mass Spectrometry, Limit of Detection, Food Safety

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review