The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Outcomes Following Subclavian and Axillary Artery Access for Transcatheter Aortic Valve Replacement
Open accessAbstract
OBJECTIVES The aim of this study was to analyze the frequency and outcomes of patients who underwent transsubclavian or transaxillary (TAx) transcatheter aortic valve replacement (TAVR) using the balloon-expandable SAPIEN 3 prosthesis compared with traditional alternative access, transapical (TA) and transaortic (TAo). BACKGROUND The transsubclavian and TAx approaches for TAVR are rapidly growing alternatives in the setting of hostile iliofemoral arteries, yet few data exist. METHODS The Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry was queried for all patients undergoing TAx TAVR with the SAPIEN 3 prosthesis from June 2015 to February 2018. Secular trends over time were evaluated. Logistic regression analyses used to assess risk-adjusted outcomes. Propensity score matching was used to compare TAx access with TA and TAo access. RESULTS In total, 3,628 patients (5.7%) underwent nontransfemoral access with the SAPIEN 3. Overall, TAx TAVR accounted for 1,249 of these patients (34.4%). There has been rapid recent growth in TAx TAVR (from 20.2% in the third quarter of 2015 to 49.0% in the fourth quarter of 2017; p < 0.001 for trend) and a concomitant decrease in TA and TAo access (from 61.9% in the third quarter of 2015 to 35.3% in the fourth quarter of 2017; p < 0.001 for trend). The median number of TAx TAVR cases per hospital during the study period was 2, and 78.2% of centers performed ≤5 TAx TAVR procedures. The device success rate was 97.3%, and the major vascular complication rate was 2.5%. After propensity matching, TAx access had lower 30-day mortality (5.3% vs. 8.4%; p < 0.01), shorter lengths of intensive care unit and hospital stay, but a higher stroke rate (6.3% vs. 3.1%; p < 0.05) compared with TA and TAo access. CONCLUSIONS TAx access has become the most frequent alternative access route for balloon-expandable TAVR procedures. Outcomes following TAx TAVR appear positive despite the relatively early experience of most centers performing these cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Cited by
2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Marin-Cuartas, M., Abreu, A., Adamo, M., Ajmone Marsan, N., Barili, F., Bonaros, N., Cosyns, B., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf194 · Cited by 1,072
Five-Year Outcomes of Transcatheter or Surgical Aortic-Valve Replacement
Makkar, R. R., Thourani, V. H., Mack, M. J., Kodali, S. K., Kapadia, S., Webb, J. G., Yoon, S.-H., Trento, A., Svensson, L. G., Herrmann, H. C., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1910555 · Cited by 832
Metadata
- Authors
- Dahle, T. G., Kaneko, T., & McCabe, J. M.
- Venue
- JACC: Cardiovascular Interventions
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 12
- Issue
- 7
- Pages
- 662-669
- ISSN
- 1876-7605 (ISSN-L)
- 1936-8798
- OpenAlex
- W2928498437
- Cited by
- 179
- References
- 1
- FWCI
- 18.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.