CoChat

Prognostic Value of QFR Measured Immediately After Successful Stent Implantation

Open access
Biscaglia, Simone, Tebaldi, Matteo, Brugaletta, Salvatore, Cerrato, Enrico, Erriquez, Andrea, Passarini, Giulia, Ielasi, Alfonso, Spitaleri, Giosafat, Di Girolamo, Domenico, Mezzapelle, Giuseppe, Geraci, Salvatore, Manfrini, Marco, Pavasini, Rita, Barbato, Emanuele, Campo, Gianluca · 2019 · JACC: Cardiovascular Interventions
Cited by 177

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVES The aim of this study was to investigate the potential role of post-percutaneous coronary intervention (PCI) quantitative flow ratio (QFR) measurements to predict clinical outcomes in patients with successful PCI. BACKGROUND The prognostic value of QFR measured immediately after PCI has not been prospectively investigated. METHODS Patients undergoing complete revascularization with successful PCI and stent implantation were eligible for acquisition of projections for QFR computation. At the end of the procedure, 2 angiographic projections for each vessel treated with PCI were acquired. Computation of QFR was performed offline by an independent core laboratory. The primary outcome was the vessel-oriented composite endpoint, defined as vessel-related cardiovascular death, vessel-related myocardial infarction, and ischemia-driven target vessel revascularization. RESULTS Seven hundred fifty-one vessels in 602 patients were analyzed. The median value of post-PCI QFR was 0.97 (interquartile range: 0.92 to 0.99). Lesion location in the left anterior descending coronary artery, baseline SYNTAX (Synergy Between PCI With Taxus and Cardiac Surgery) score, lesion length, and post-PCI diameter stenosis were found to be predictors of lower post-PCI QFR. Altogether, 77 events were detected in 53 treated vessels (7%). Post-PCI QFR was significantly lower in vessels with the vessel-oriented composite endpoint during follow-up, compared with those without it (0.88 [interquartile range: 0.81 to 0.99] vs. 0.97 [interquartile range: 0.93 to 0.99], respectively; p < 0.001). Receiver operating characteristic curve analysis identified a post-PCI QFR best cutoff of ≤0.89 (area under the curve 0.77; 95% confidence interval: 0.74 to 0.80; p < 0.001). After correction for potential confounding factors, post-PCI QFR ≤0.89 was associated with a 3-fold increase in risk for the vessel-oriented composite endpoint (hazard ratio: 2.91; 95% confidence interval: 1.63 to 5.19; p < 0.001). CONCLUSIONS Lower values of QFR after complete and successful revascularization predict subsequent adverse events (Angio-Based Fractional Flow Reserve to Predict Adverse Events After Stent Implantation [HAWKEYE]; NCT02811796).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcin.2019.06.003

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 177

Metadata

Authors
Biscaglia, S., Tebaldi, M., Brugaletta, S., Cerrato, E., Erriquez, A., Passarini, G., Ielasi, A., Spitaleri, G., Di Girolamo, D., Mezzapelle, G., Geraci, S., Manfrini, M., Pavasini, R., Barbato, E., & Campo, G.
Venue
JACC: Cardiovascular Interventions
Publisher
Elsevier BV
Published
2019-10
Volume
12
Issue
20
Pages
2079-2088
ISSN
  • 1876-7605 (ISSN-L)
  • 1936-8798
OpenAlex
W2975856547
Cited by
177
References
1
FWCI
15.12
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.