Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 211

The DOI matches its Crossref record.

Coronary Cannulation After Transcatheter Aortic Valve Replacement

Open access
Barbanti, Marco, Costa, Giuliano, Picci, Andrea, Criscione, Enrico, Reddavid, Claudia, Valvo, Roberto, Todaro, Denise, Deste, Wanda, Condorelli, Antonio, Scalia, Matteo, Licciardello, Alessandra, Politi, Giorgia, De Luca, Giuseppe, Strazzieri, Orazio, Motta, Silvia, Garretto, Valeria, Veroux, Pierfrancesco, Giaquinta, Alessia, Giuffrida, Angelo, Sgroi, Carmelo, Leon, Martin B., Webb, John G., Tamburino, Corrado · 2020 · JACC: Cardiovascular Interventions

Abstract

OBJECTIVES The aims of this study were to investigate the feasibility of coronary ostia cannulation after transcatheter aortic valve replacement (TAVR) and to assess potential predictors of coronary access impairment. BACKGROUND Certain data concerning the feasibility and reproducibility of coronary cannulation after TAVR are lacking. METHODS RE-ACCESS (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent) was an investigator-driven, single-center, prospective, registry-based study that enrolled consecutive patients undergoing TAVR using all commercially available devices. All patients underwent coronary angiography before and after TAVR. The primary endpoint was the rate of unsuccessful coronary ostia cannulation after TAVR. Secondary endpoints were the identification of factors associated with the inability to selectively cannulate coronary ostia after TAVR. RESULTS Among 300 patients enrolled in the RE-ACCESS study from December 2018 to January 2020, a total of 23 cases (7.7%) of unsuccessful coronary cannulation after TAVR were documented. This issue occurred in 22 of 23 cases with the use of Evolut R/PRO transcatheter aortic valves (TAVs) (17.9% vs. 0.4%; p < 0.01). In multivariate analysis, the use of Evolut R/PRO TAVs (odds ratio [OR]: 29.6; 95% confidence interval [CI]: 2.6 to 335.0; p < 0.01), the TAV-sinus of Valsalva relation (OR: 1.1 per 1-mm increase; 95% CI: 1.0 to 1.2; p < 0.01), and the mean TAV implantation depth (OR: 1.7 per 1-mm decrease; 95% CI: 1.3 to 2.3; p < 0.01) were found to be independent predictors of unsuccessful coronary cannulation after TAVR. A model combining these factors was demonstrated to predict with very high accuracy the risk for unsuccessful coronary cannulation after TAVR (area under the curve: 0.94; p < 0.01). CONCLUSIONS Unsuccessful coronary cannulation following TAVR was observed in 7.7% of patients and occurred almost exclusively in those receiving Evolut TAVs. The combination of Evolut TAV, a higher TAV-sinus of Valsalva relation, and implantation depth predicts with high accuracy the risk for unsuccessful coronary cannulation after TAVR. (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent (RE-ACCESS); NCT04026204).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcin.2020.07.006

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 211

Metadata

Authors
Barbanti, M., Costa, G., Picci, A., Criscione, E., Reddavid, C., Valvo, R., Todaro, D., Deste, W., Condorelli, A., Scalia, M., Licciardello, A., Politi, G., De Luca, G., Strazzieri, O., Motta, S., Garretto, V., Veroux, P., Giaquinta, A., Giuffrida, A., Sgroi, C., Leon, M. B., Webb, J. G., & Tamburino, C.
Venue
JACC: Cardiovascular Interventions
Publisher
Elsevier BV
Published
2020-11
Volume
13
Issue
21
Pages
2542-2555
ISSN
  • 1876-7605 (ISSN-L)
  • 1936-8798
OpenAlex
W3093208061
Cited by
211
References
0
FWCI
15.36
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Coronary Cannulation After Transcatheter Aortic Valve Replacement. https://app.cochat.ai/papers/10.1016/j.jcin.2020.07.006
The paper
Barbanti, M., Costa, G., Picci, A., Criscione, E., Reddavid, C., Valvo, R., Todaro, D., Deste, W., Condorelli, A., Scalia, M., Licciardello, A., Politi, G., De Luca, G., Strazzieri, O., Motta, S., Garretto, V., Veroux, P., Giaquinta, A., Giuffrida, A., . . . Tamburino, C. (2020). Coronary Cannulation After Transcatheter Aortic Valve Replacement. JACC: Cardiovascular Interventions. https://doi.org/10.1016/j.jcin.2020.07.006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.