CoChat

Drug-Coated Balloon Versus Drug-Eluting Stent for Small Coronary Vessel Disease

Open access
Cortese, Bernardo, Di Palma, Gaetano, Guimaraes, Marcos Garcia, Piraino, Davide, Orrego, Pedro Silva, Buccheri, Dario, Rivero, Fernando, Perotto, Anna, Zambelli, Giulia, Alfonso, Fernando · 2020 · JACC: Cardiovascular Interventions
Cited by 234

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

OBJECTIVES This study sought to compare the performance of a novel drug-coated balloon (DCB) (Elutax SV, Aachen Resonance, Germany), with an everolimus-eluting stent (EES) (Abbott Vascular, Santa Clara, California) in patients with de novo lesions. BACKGROUND Small vessel coronary artery disease (SVD) represents one of the most attractive fields of application for DCB. To date, several devices have been compared with drug-eluting stents in this setting, with different outcomes. METHODS The PICCOLETO II (Drug Eluting Balloon Efficacy for Small Coronary Vessel Disease Treatment) trial was an international, investigator-driven, multicenter, open-label, prospective randomized controlled trial where patients with de novo SVD lesions were randomized to DCB or EES. Primary study endpoint was in-lesion late lumen loss (LLL) at 6 months (independent core laboratory), with the noninferiority between the 2 arms hypothesized. Secondary endpoints were minimal lumen diameter, percent diameter stenosis at angiographic follow-up, and the occurrence of major adverse cardiac events at 12 months. RESULTS Between May 2015 and May 2018, a total of 232 patients were enrolled at 5 centers. After a median of 189 (interquartile range: 160 to 202) days, in-lesion LLL was significantly lower in the DCB group (0.04 vs. 0.17 mm; p = 0.001 for noninferiority; p = 0.03 for superiority). Percent diameter stenosis and minimal lumen diameter were not significantly different. At 12-month clinical follow-up, major adverse cardiac events occurred in 7.5% of the DES group and in 5.6% of the DCB group (p = 0.55). There was a numerically higher incidence of spontaneous myocardial infarction (4.7% vs. 1.9%; p = 0.23) and vessel thrombosis (1.8% vs. 0%; p = 0.15) in the DES arm. CONCLUSIONS In this multicenter randomized clinical trial in patients with de novo SVD lesions, a new-generation DCB was found superior to EES in terms of LLL as the angiographic pattern and comparable in terms of clinical outcome. (Drug Eluting Balloon Efficacy for Small Coronary Vessel Disease Treatment [PICCOLETO II]; NCT03899818).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcin.2020.08.035

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Metadata

Authors
Cortese, B., Di Palma, G., Guimaraes, M. G., Piraino, D., Orrego, P. S., Buccheri, D., Rivero, F., Perotto, A., Zambelli, G., & Alfonso, F.
Venue
JACC: Cardiovascular Interventions
Publisher
Elsevier BV
Published
2020-12
Volume
13
Issue
24
Pages
2840-2849
ISSN
  • 1876-7605 (ISSN-L)
  • 1936-8798
OpenAlex
W3109156174
Cited by
234
References
15
FWCI
18.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Drug-Coated Balloon Versus Drug-Eluting Stent for Small Coronary Vessel Disease. https://app.cochat.ai/papers/10.1016/j.jcin.2020.08.035
The paper
Cortese, B., Di Palma, G., Guimaraes, M. G., Piraino, D., Orrego, P. S., Buccheri, D., Rivero, F., Perotto, A., Zambelli, G., & Alfonso, F. (2020). Drug-Coated Balloon Versus Drug-Eluting Stent for Small Coronary Vessel Disease. JACC: Cardiovascular Interventions. https://doi.org/10.1016/j.jcin.2020.08.035

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.