The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Long-term antibacterial stable reduced graphene oxide nanocomposites loaded with cuprous oxide nanoparticles
Abstract
Stable reduced graphene oxide-cuprous oxide (rGO-Cu2O) nanocomposites with long-term antibacterial activities were prepared by reducing copper sulfate supported on GO using ascorbic acid as reducing agent in the presence of polyethylene glycol (PEG) and sodium hydroxide at room temperature. The rGO provided a protective barrier for Cu2O, preventing Cu2O from reacting with external solution to leach copper ions too quickly. Meanwhile, the rGO also promoted the separation of photoexcited charge carriers of Cu2O nanoparticles to enhance the oxidative stress reactive and protected Cu2O from falling apart in the phosphate buffered solution (PBS) solution to prolong the generation time of reactive oxygen species (ROS). More importantly, the large specific surface area of rGO improved the dispersibility of Cu2O by electrostatic interaction. The synergistic effect of sustained release of copper ions, elevated ROS production ability and uniform dispersion of rGO-Cu2O nanocomposites resulted in the excellent antibacterial activities of rGO-Cu2O nanocomposites against Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) which were maintained around 70% and 65% and were increased by 40% and 35% compared with free Cu2O after immersing 30 days in PBS solutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kittler, S., Greulich, C., Diendorf, J., Köller, M., & Epple, M. (2010) · Chemistry of Materials · doi:10.1021/cm100023p · Cited by 1,126
Gao, Z., Wang, J., Li, Z., Yang, W., Wang, B., Hou, M., He, Y., Liu, Q., Mann, T., Yang, P., et al. (2011) · Chemistry of Materials · doi:10.1021/cm200975x · Cited by 542
Cited by
Electrically conductive polymer composites for smart flexible strain sensors: a critical review
Liu, H., Li, Q., Zhang, S., Yin, R., Liu, X., He, Y., Dai, K., Shan, C., Guo, J., Liu, C., et al. (2018) · Journal of Materials Chemistry C · doi:10.1039/c8tc04079f · Cited by 709
Self-citationAntibacterial Properties of Graphene-Based Nanomaterials
Kumar, P., Huo, P., Zhang, R., & Liu, B. (2019) · Nanomaterials · doi:10.3390/nano9050737 · Cited by 512
MXenes Antibacterial Properties and Applications: A Review and Perspective
Seidi, F., Arabi Shamsabadi, A., Dadashi Firouzjaei, M., Elliott, M., Saeb, M. R., Huang, Y., Li, C., Xiao, H., & Anasori, B. (2023) · Small · doi:10.1002/smll.202206716 · Cited by 291
Metadata
- Authors
- Yang, Z., Hao, X., Chen, S., Ma, Z., Wang, W., Wang, C., Yue, L., Sun, H., Shao, Q., Murugadoss, V., & Guo, Z.
- Venue
- Journal of Colloid and Interface Science
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 533
- Pages
- 13-23
- ISSN
- 0021-9797 (ISSN-L)
- OpenAlex
- W2887065277
- Cited by
- 303
- References
- 2
- FWCI
- 15.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long-term antibacterial stable reduced graphene oxide nanocomposites loaded with cuprous oxide nanoparticles. https://app.cochat.ai/papers/10.1016/j.jcis.2018.08.053
- The paper
- Yang, Z., Hao, X., Chen, S., Ma, Z., Wang, W., Wang, C., Yue, L., Sun, H., Shao, Q., Murugadoss, V., & Guo, Z. (2019). Long-term antibacterial stable reduced graphene oxide nanocomposites loaded with cuprous oxide nanoparticles. Journal of Colloid and Interface Science. https://doi.org/10.1016/j.jcis.2018.08.053
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.