Abstract

The integration of pyrolysis and prepositive anaerobic digestion could be a solution to improve energy recovery from sewage sludge. However, it is not clear whether this integrated pathway always outperforms the two single technologies when dealing with different types of sludge. In this study, the integrated pathway is compared with anaerobic digestion and pyrolysis from the points of view of life cycle environmental impacts and energy efficiency. In addition, the effect of the organic content in the feed sludge on the performance of the three pathways is investigated. The results indicated that the environmental impacts of the three pathways are heavily dependent on their energy inputs and outputs. The single pyrolysis pathway exhibited the lowest energy efficiency and the heaviest environmental burden, and only the sludge with volatile solids in total solids (VS/TS) higher than 63% allowed the system generate a net energy output. The integrated pathway had better environmental performance and energy efficiency than single pyrolysis because prepositive anaerobic digestion enhanced the conversion of sludge organic matter to energy. When sludge VS/TS exceeded 61%, the integrated system exported surplus heat. Anaerobic digestion performed the best among the three pathways because it required no energy and material expenditure for thermal drying and pyrolysis. Also, a VS/TS of 52% in the feed sludge corresponded to the balance point for equal energy input and output. Therefore, anaerobic digestion should be the first choice when designing a sewage sludge disposal system. The integrated pathway is an alternative for high organic content sludge because of its high conversion rate of sludge to energy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jclepro.2018.05.259

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 131

Metadata

Authors
Li, H., & Feng, K.
Venue
Journal of Cleaner Production
Publisher
Elsevier BV
Published
2018-09
Volume
195
Pages
476-485
ISSN
0959-6526 (ISSN-L)
OpenAlex
W2805119808
Cited by
131
References
1
FWCI
9.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Life cycle assessment of the environmental impacts and energy efficiency of an integration of sludge anaerobic digestion and pyrolysis. https://app.cochat.ai/papers/10.1016/j.jclepro.2018.05.259
The paper
Li, H., & Feng, K. (2018). Life cycle assessment of the environmental impacts and energy efficiency of an integration of sludge anaerobic digestion and pyrolysis. Journal of Cleaner Production. https://doi.org/10.1016/j.jclepro.2018.05.259

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.