Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 184

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Assessment and development of high-performance fibre-reinforced lightweight self-compacting concrete including recycled crumb rubber aggregates exposed to elevated temperatures

Aslani, Farhad, Kelin, Jack · 2018 · Journal of Cleaner Production

Abstract

Abstract Recycled crumb rubber is a material created by grinding and commutating used tyres. There is no doubt that the increasing piles of tyres create environmental concerns. The long term goal of this paper is to find a means to dispose of the crumb rubber in lightweight self-compacting concrete (SCC) and still provide a final product with good engineering properties. This paper has considered replacement of natural normal-weight aggregates with crumb rubber aggregates and lightweight scoria aggregate together with the addition of macro fibres which provides a sustainable alternative which assists in minimizing the environmental damages associated with the disposal of waste tyres. Also, the purpose of this study is to determine the effect of fibres on fresh and mechanical properties in additional to the performance of the concrete after exposure to elevated temperatures. Investigation has been performed after concrete exposure to both room and elevated temperatures. Fibre reinforcement were added to a control mix containing 80% replacement of traditional coarse aggregate with lightweight scoria aggregate and 20% replacement of traditional fine aggregate with crumb rubber aggregate. Steel and polypropylene (PP) fibres were explored so as to ascertain the benefits each fibre can provide through a range of temperatures. Nine mixes were prepared; a control mix and four mixes per each fibre with increasing fibre addition. Chemical admixture dosages were adjusted so as to achieve the desired slump flow. Experimental program investigated the fresh properties of the SCC through slump flow, slump flow T500 and J-ring tests. Mechanical properties were investigated after 28 days curing, standard 100 × 200 mm cylinder specimens were subjected to compressive and indirect tensile tests after exposure to 25, 100, 300, 600 and 900 °C. Compiled results will be compared to those of the control mix.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jclepro.2018.07.323

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Aslani, F., & Kelin, J.
Venue
Journal of Cleaner Production
Publisher
Elsevier BV
Published
2018-11
Volume
200
Pages
1009-1025
ISSN
0959-6526 (ISSN-L)
OpenAlex
W2887097893
Cited by
184
References
1
FWCI
13.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.