Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 231

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Transfer learning with deep neural networks for model predictive control of HVAC and natural ventilation in smart buildings

Chen, Yujiao, Tong, Zheming, Zheng, Yang, Samuelson, Holly, Norford, Leslie · 2020 · Journal of Cleaner Production

Abstract

Abstract Advanced control strategies are central components of smart buildings. For model-based control algorithms, the quality of the model that represents building systems and dynamics is essential to guarantee satisfactory performance of smart building control and automation. For the model predictive control of the heating, ventilation, and air conditioning systems in buildings coupled with natural ventilation, a high-fidelity model is necessary to reliably predict the thermal responses of the building under various environmental and operational conditions. This task can be accomplished by using a deep neural network, which can capture the dynamics of complicated physical processes, such as natural ventilation. Training a deep neural network requires the collection of a large amount of data; however, in practice, the target building may not have enough operational data available. This study demonstrates how transfer learning could help with this dilemma. By freezing most layers of a deep neural network model with 42,902 parameters that are pre-trained on multi-year data from a source room in Beijing, the model can be re-trained with only 200 trainable parameters on only 15 days of data from the target room in Shanghai that has entirely different floor area, building material, and window size. The proposed transfer learning model achieves high accuracy predicting both indoor air temperature and relative humidity for a time horizon from 10 minutes to 2 hours, showing the mean squared error almost one magnitude smaller than the comparison model that is only trained on source data or target data. This methodology can be applied to the design of the control system in a new building which reduces the required amount of data for the training of the model, thus saving costs in control system design and commissioning.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jclepro.2019.119866

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 231

Metadata

Authors
Chen, Y., Tong, Z., Zheng, Y., Samuelson, H., & Norford, L.
Venue
Journal of Cleaner Production
Publisher
Elsevier BV
Published
2020-05
Volume
254
Pages
119866
ISSN
0959-6526 (ISSN-L)
OpenAlex
W2997051579
Cited by
231
References
6
FWCI
18.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.