CoChat

Highly efficient capture of phosphate from water via cerium-doped metal-organic frameworks

Liu, Meng, Li, Shengjian, Tang, Nian, Wang, Yating, Yang, Xiangjun, Wang, Shixiong · 2020 · Journal of Cleaner Production
Cited by 221

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

A highly effective and neoteric cerium-doped metal-organic framework (MOF Ce-UiO-66-NH2) was triumphantly prepared via a simple and convenient approach of solvothermal reaction; the Ce-UiO-66-NH2 can be used for removing phosphate from water. The physicochemical characteristics of new adsorbent were determined by X-ray diffraction (XRD), Brunauer–Emmett–Teller analysis (BET), transmission electron microscopy (TEM), scanning electron microscopy (SEM), and infrared spectroscopy (FTIR). The results confirmed that the introduction of cerium caused a trivial effect on the UiO-66-NH2 structure; however, a hybrid MOF with polyhedral crystalloid shapes was obtained. When cerium was doped in UiO-66-NH2, the newly developed adsorbent Ce-UiO-66-NH2 exhibited outstanding performance in terms of adsorption of phosphate, and the maximum uptake capacity was up to 211.86 mg g−1. The reaction for capture of phosphate of 0.75Ce-UiO-66-NH2 was quite fast, and could reach equilibrium in 60 min. Furthermore, FTIR and X-ray photoelectron spectroscopy (XPS) characterization indicated that the main mechanism of phosphate capture involved the production of an inner-sphere complex of Zr/Ce–O–P and electrostatic attraction. After adsorption, the phosphate on Ce-UiO-66-NH2 was efficiently desorbed with NaOH (0.10 mol L−1); thus the material could be used repeatedly for at least five cycles, and the adsorption capacity was still more than 100 mg g−1 at the fifth cycle. The repeated utilization potentially provides access to effectively prevent water pollution and further implement cleaner production at the minimum cost. The developed Ce-UiO-66-NH2 is an efficient and regenerative adsorbent that can be used for phosphate uptake to mitigate increasing eutrophication of water.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jclepro.2020.121782

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 221

Metadata

Authors
Liu, M., Li, S., Tang, N., Wang, Y., Yang, X., & Wang, S.
Venue
Journal of Cleaner Production
Publisher
Elsevier BV
Published
2020-08
Volume
265
Pages
121782
ISSN
0959-6526 (ISSN-L)
OpenAlex
W3019304978
Cited by
221
References
3
FWCI
15.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly efficient capture of phosphate from water via cerium-doped metal-organic frameworks. https://app.cochat.ai/papers/10.1016/j.jclepro.2020.121782
The paper
Liu, M., Li, S., Tang, N., Wang, Y., Yang, X., & Wang, S. (2020). Highly efficient capture of phosphate from water via cerium-doped metal-organic frameworks. Journal of Cleaner Production. https://doi.org/10.1016/j.jclepro.2020.121782

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.